Step 5. FIELD WIRING

CAUTION
Ground supply lead must be con-
nected to the wire attached to the
green ground screw located on the
outlet box. See
Figures 50 & 51
ure to do so will result in a potential
safety hazard. The appliance must be
electrically grounded in accordance
with local codes or, in the absence of
local codes, the National Electrical
Code, ANSI/NFPA 70-latest edition.,
or the Canadian Electrical Code, CAN/
CGA C22.1—latest edition.
CAUTION: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors
can cause improper and dangerous operation.
ATTENTION: Au moment de l'entretien des
commandes, étiquetez tous les fils avant de
les débrancher. Des erreurs de cáblage peu-
vent entraîner un fonctionnement inadéquat
et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
Refer to Section A for electronic appliances.
The gas valve is set in place and pre-wired at
the factory on both models.
A. Electronic Wiring (See Figure 52)
NOTE: The electronic appliance must be con-
nected to the main 120 VAC power supply.
NOTE: The junction box can be installed in any of
the 4 outside corners of the control compartment
(outlet installed in front left corner is shown in
Figure 51). If an optional blower is to be installed
. Fail-
place the junction box to the right of the valve
in the front corner.
1. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power
supply to the location on appliance where
junction box is to be installed.
2. Open the control compartment access panel.
3. Wire and install the outlet receptacle to
junction box, then install into the chosen
corner of the control compartment as shown
in Figures 50 and 52.
4. After the receptacle/junction box wiring is
complete, install the provided metal junction
box cover plate (see Figure 51, page 30).
5. Install the snap bushing (on brown wall switch
wire) into the selected cabinet knockout
opening in side cabinets (see Figures 16-19
and 51). The snap bushing provides protec-
tion for the wires (see note below) passing
through side cabinet going to an optional
burner control switch Wire in the burner
control switch to the low voltage circuit as
shown in Figure 52, page 30.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900299-00, 02/2019
NOTE: The supplied 15 feet of brown
2-conductor wire has one end of each conductor
connected to the gas valve circuit and the other
end of each conductor placed loose on bottom
of the appliance.
IMPORTANT NOTE: The gas valve OFF/ON
switch is shown in Figure 52 on Page 30. It
is integral with the gas valve and should be set
to the ON position.
WARNING
Electronic models of these appli-
ances are equipped with a three-
prong (grounding) plug utilized
in connecting the electronic
components to the junction box
in the lower compartment. This
grounding plug provides protec-
tion against shock hazard and
should be plugged directly into
the properly grounded three-
prong receptacle. DO NOT cut
or remove the grounding prong
from the plug.
Ground Wire
Connection
White
(supply)
Black
(supply)
NOTE: Supply wires may be alternatively con-
nected to the outlet using the screw terminals,
however the black supply wire must be wired to
a terminal that is opposite (across the outlet) the
point where the white supply wire is connected.