OPERATION

Pre-Lighting Checklist

Be sure to check these items before the initial lighting of the insert:
c Gas pressure has been checked carefully - see Page 20.
c All gas fittings have been checked for leaks.
c All clearances to combustibles have been met-see Page 14.
c All combustible materials have been removed from the area
in front of the insert.
c All vented areas of the insert face are unobstructed.
c House is ventilated to clear initial paint curing odors - see
Page 23.
c All packaging materials have been removed from the firebox.
c Firebox liner panels and log set have been installed.
c The glass door is in place and is properly sealed.
c The accent light bulb has been installed.

Operating Instructions

See lighting instructions on Page 38.

Intermittent/Standing Pilot Mode

This appliance can be switched from intermittent ignition to a standing
pilot (see Figure 23). The IPI/CPI rocker switch is located at the bottom
of the left Full Front Facade panel (OFF [o]= Intermittent Pilot Mode and
ON [-] = Standing Pilot Mode). To save energy, switch to intermittent
mode. To have a standing pilot which will help startup during cold climate
conditions by warming the flue and the glass, switch to standing pilot.
The standing pilot mode is indicated by a pilot that comes on and remains
lit when the fireplace is off.
22
Room Air Circulation Blower
Plug in the three-prong power cord into the provided J-Box/Receptacle
(see Figure 22). Do not cut or remove the grounding prong from the
power cord.
The blower ON/OFF-Speed control switch is located on the left side Full
Front Facade.
BK = Black
R = Red
W = White
GR = Green
Standard Blower
Figure 22 - Blower / J-Box
Control switches and the blower speed control knob (rheostat)
are mounted on the outside edge of the left side of the Full
Front Facade as shown below.
ON/OFF Switch turns the burner
on and off.
Hi-Low Switch controls the main
burner flame height.
Pilot (IPI/CPI) Switch is for stand-
ing pilot mode [IPI -] or Intermittent
pilot mode [CPI o].
Pair Remote (Learn Switch) is for
programming the optional remote
control (see instructions provided
with the remote control).
On/Off Blower Speed Control Knob
turns the blower on and off and
controls the speed of the blower.
Figure 23 - Control Switches on Left Side Full Front Facade
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Blower ON/OFF-Speed Control
Switch (rheostat) on Full Front Facade
BK
BK
R
GR
120 V
Standard J-Box
W
AC