Innovative Hearth Products
DRT40 Multi-View Series Direct-Vent Gas Fireplace

GAS CONVERSION KITS

This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in
these instruction is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage, personal injury
or loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the manu-
facturer's instructions supplied with the kit.The qualified service agency
performing this installation assumes responsibility for this conversion.
Cette trousse de conversion doit être installée par un technicien agréé,
selon les instructions du fabricant et selon toutes les exigences et tous les
codes pertinents de l'autorité compétente. Assurez-vous de bien suivre
les instructions dans cette notice pour réduire au minimum le risque
d'incendie, d'explosion ou la production de monoxyde de carbone pouvant
causer des dommages matériels, des blessures ou la mort. Le tecnicien
agréé est responsable de l'installation de cette trousse. L'installation n'est
pas adéquate ni complète tant que le bon fonctionnement de l'appareil
converti n'a pas été vérifié selon les instructions du fabricant fournies avec
la trousse. Le fournisseur de service qualifié ayant réalisé l'installation
assume les responsabilités liées à la conversion.
In Canada:
THE CONVERSION SHALL BE CAR-
RIED OUT IN ACCORDANCE WITH THE
REQUIREMENTS OF THE PROVINCIAL
AUTHORITIES HAVING JURISDICTION
AND IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE CAN/CGA-B149.1
INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EF-
FECTUÉE CONFORMÉMENT AUX RE-
COMMANDATIONS DES AUTORITÉS
PROVINCIALES AYANT JURIDICTION
ET CONFORMÉMENT AUX EXIGENCES
DU CODE D'INSTALLATION CAN/CGA-
B149.1.
Gas conversion kits are available to adapt your
appliance from the use of one type of gas to
the use of another. These kits contain all the
necessary components needed to complete the
task including labeling that must be affixed to
ensure safe operation.
Kit part numbers are listed here and the
following steps detail the conversion proce-
dure. Refer to the instructions provided with
the conversion kit when performing any gas
conversion.
42
WARNING
AVERTISSEMENT
Natural to Propane Conversion Kit
Models
Unit type
ST and PF
Electronic
CL and CR
Electronic
INSTALLATION INSTRUCTIONS
Step 1. TURN OFF THE GAS SUPPLY TO THE
APPLIANCE and disconnect power supply at the
circuit breaker. Ensure appliance is cold.
CAUTION: THE GAS SUPPLY SHALL BE
SHUT OFF PRIOR TO DISCONNECTING THE
ELECTRICAL POWER, BEFORE PROCEED-
ING WITH THE CONVERSION.
ATTENTION: AVANT D'EFFECTUER
LA CONVERSION, COUPEZ D'ABORD
L'ALIMENTATION EN GAZ, ENSUITE,
COUPEZ L'ALIMENTATION ÉLECTRIQUE.
a. Open the control compartment access panel,
by lifting panel approximately 1/2" to disengage
and swing the panel open from top.
b. Remove the bottom control compartment
access panel by compressing the spring-loaded
hinge pin on the left side until it disengages from
the left cabinet panel hole. Pull the panel away
from the fireplace.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
c. Remove the modesty panel by pulling the
bottom right corner of the modesty panel out
slightly to disengage the snap-fit feature; lift the
modesty panel by the tab on the panel's right
end, pull the right end of the panel away from
the cabinet and then pull the panel diagonally
out of the left side cabinet panel slots. (In the
above procedure, reverse the words "left" and
"right" for DRT40CR models). Remove the
modesty panel carefully, so that none of the
wires become loose or disconnected.
d. Locate the two (2) latches at the top of the
control compartment. To disengage the two
latches from the bottom vee-flange of the glass
enclosure panel, reach for the handles located
towards the back of the latches and pull the
handles down toward the front of the unit. See
Figure 60 on Page 36.
e. Swing the bottom of the door out and raise
it slightly to lift the top flange of the door frame
away from the appliance.
Step 2. Carefully remove the log set. Exercise
care as not to break the log set.
Step 3. Referring to Figure 64, remove the
burner.
AIR SHUTTER
ADJUSTMENT LEVER
Catalog No.
F2316
FIREBOX SUBFLOOR
F2317
Figure 64
Electronic Appliances
Step 4. Honeywell Electronic Valves - See
Figure 65 and the instructions provided with
the kit. Remove the slotted cap screw, o-ring,
pressure-regulating adjusting screw and spring.
Retain all parts for possible later use. Install
new components from the kit. Black cap and
red spring for propane gas units. Silver cap
and stainless steel spring for natural gas units.
Before installing the cap, attach manometer to
the manifold side pressure test fitting and adjust
screw until pressure reads 3.5 inches water
column (0.87 kPa) for natural gas, and 10.0
inches water column (2.49 kPa) for propane gas.
See Figure 66 and replace the pilot orifice as
follows: Remove the igniter assembly retainer
clip, and carefully remove the igniter assembly.
Installation and Operation Instructions
900299-00, 02/2019
PAN BURNER
VENTURI TUBE ARM
FRONT OF FIREPLACE