Install The [Optional] Blower Kit After Installation In The Framing - Superior Fireplaces DRT3000 Series Installation And Operation Instructions Manual

Direct-vent gas fireplaces
Hide thumbs Also See for DRT3000 Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT3000 and DRC3000 Series Direct-Vent Gas Fireplaces
6. If a wall-mounted ON/OFF control, High/Low switch, or thermostat is to be used, mount it in a convenient location on a wall
near the fireplace.
7. If an optional control is to be used, wire it in the low voltage circuit (Figures 30-31).
NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit
and the other end of each conductor placed loose inside the bottom compartment.
8. After the wiring is complete, replace the cover plate.
Electronic models of these appliances are equipped with a three-prong (grounding)
plug utilized in connecting the electronic components to the junction box in the lower
compartment. This grounding plug provides protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the
grounding prong from the plug.
Figure 31 - Wiring Diagram— Ecoflow Electronic Gas Valves
Burner 2
Valve
Step
Motor
Inlet
Valve
Step
Motor
Gas Valve
Optional
Fixed
Outlet
(Some Models)

Install the [Optional] Blower Kit after Installation in the Framing

12.
NOTE: For steps 11 and 12, it may be helpful to remove the control compartment door (Page 53).
FBK-100, FBK-200, and FBK-250 Kits
An electrical outlet box is provided for the installation of the FBK-100, FBK-200, and FBK-300 forced air blower kits.
Electrical power must be provided to the box to operate the blower. Install the blower kit according to the installation
instructions provided with the kit.
NOTE: The tab connecting the receptacles of the outlet box must be broken in FBK-100 and FBK-200 blower kit
applications (Figure 32).
Main Burner
Thermocouple Ground -
Connector to Chassis
Ground or Valve Body
Thermocouple - To "S"
Terminal on Main Module
Dry -
Learn (Black) (Some Models)
Contact
Optional: IPI/Cont. Pilot (Yellow)
Switches
Optional: Hi/Lo (Blue)
Battery
On/Off (Brown)
Pack
" – "
Black
(Primary or
Backup)
" + "
Red
Power Vent Models Only
Proof Out:
Dry Contact Only!
Norm. Open
Draft SW
Draft Call
Input
PV Call
(Green)
(White)
Valve
Safety Operator
From Pilot
Thermocouple
To Pilot
Igniter
Regulator
Inlet
WARNING
Ecoflow Electronic
Pilot
7.5VDC
1-Amp
Switching
Adaptor
(Not Polarity
Sensitive)
SWITCHES
POWER
120 V Power
Installation
900285-00 12/2016
Gas Valve
Some Models
GREEN
BLOWER
G
LIGHTS
AUX
COMM
VCS-ECOEXTMOD
(Extension Module)
FAN
MOTOR
Supply
39