Burner Flame Adjustments; Electronic Appliance Checkout - Superior Fireplaces DRT40 Series Installation And Operation Instructions Manual

Multi-view direct-vent gas fireplaces
Hide thumbs Also See for DRT40 Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT40 Multi-View Series Direct-Vent Gas Fireplace

BURNER FLAME ADJUSTMENTS

WARNINGS
• Air shutter adjustment should
only be performed by a quali-
fied professional service tech-
nician.
• Ensure front glass panel are
in place and sealed during
adjustment.
CAUTIONS
• Soot will be produced if the
air shutter is closed too much.
Any damage due to sooting,
resulting from improperly
setting the air shutter, is not
covered under the warranty.
• The air shutter door and
nearby appliance surfaces
are hot. Exercise caution to
avoid injury while adjusting
flame appearance.
1. Refer to Figure 75 for proper flame ap-
pearance. To adjust the flame, rotate the
adjustment rod toward the back or toward
the front of the fireplace (rod located in
the lower control area). Position the air
shutter to the factory setting as shown in
the table in Figure 76.
2. Light appliance (follow lighting procedure
on lighting label in control compartment
or see the Care and Operation Manual).
3. Allow the burner to operate for at least 15
minutes while observing the flame con-
tinuously to ensure that the proper flame
appearance has been achieved. If the
following conditions are present, adjust
accordingly.
• If flame appears weak or sooty, adjust
the air shutter, incrementally, to a
more open position until the proper
flame appearance is achieved.
• If flame remains blue, adjust the air
shutter, incrementally, to a more
closed position until the proper flame
appearance is achieved.
4. Leave the control knob (off/pilot/on)
in the ON position and the burner OFF/
ON switch OFF (and remote switches, if
applicable).
5. When satisfied that the burner flame ap-
pearance is normal, re-install the lower
control compartment door then proceed
to finish the installation.
Air Shutter
Adjusting
Rod
Orifice
Increase Shutter
Opening In This
Direction
Decrease Shutter
Opening In This
Direction
Note - Burners are omitted in this view for clarity.
Note: The gas valve of your fireplace may be dif-
ferent in appearance
MAIN BURNER
FACTORY SHUTTER SETTING
Models
Natural Gas
Propane Gas
inches (mm)
inches (mm)
DRT40ST
DRT40PF
1/4"
DRT40CL
(6.35)
DRT40CR
Adjustment Rod Positions (when viewed from above)
Figure 76
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Electronic Appliance Checkout

To light the burner, turn 'ON' the unit mounted
On/Off switch or the optional remote wall switch.
Ensure the igniter lights the pilot. The pilot
flame should engulf the flame rod as shown
in Figure 77.
ELECTRONIC
Proper Flame
Adjustment
Pilot
Nozzle
Figure 77
5/8"
(15.88)
Installation and Operation Instructions
900299-00, 02/2019
3/8 To 1/2 Inch
(9 mm to 13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drt40stdenDrt40pfdenDrt40cldenDrt40crden

Table of Contents