T-Bar Re-Calibration
After a firmware update of the switcher it will be necessary to re-calibrate the T-Bar to get it
working correctly.
Move the T-Bar to its lowest position.
1.
Power OFF the HS-2850 switcher.
2.
Press and hold down button 1 on both the
3.
Program and Preset rows of the switcher's
keyboard.
Power ON the HS-2850 switcher while still holding
4.
down the buttons in step 3.
The switcher will start but the keyboard lights will
5.
remain dead except for the T-Bar progress LEDs.
When these LEDs flash ON and OFF release the
buttons from step 3.
Move the T-Bar to almost its top position (2-3mm
6.
away) and then press the CUT button.
Move the T-Bar back to almost its lowest position
7.
(2-3mm away) and then press the AUTO TAKE
button.
To exit the calibration procedure, press the CLOCK
8.
button.
Ensure the TIMER button is OFF.
9.
Test the T-Bar. If necessary change the T-Bar Mode
10.
in the OSD MENU options.
77