KBL megaSun 7900 Alpha Operating Instructions Manual page 57

Hide thumbs Also See for megaSun 7900 Alpha:
Table of Contents

Advertisement

After the error has been eliminated, all error messages must be acknowledged by pressing START on the interior control panel.
No.
Status message
Frequency detection: power
26
supply
connection
(connector X6/E6)!
No.
Info. message
Fill level aquaCool canister
203
low
Connection aquaCool unit
204
faulty
Connection audio module
205
faulty
Connection inside display
206
faulty
207
aquaCool canister empty
Aroma supply low, please
208
renew
aircon:
condensed-water
209
canister full, please empty
Low battery charge, please
210
renew
Connection preselect display
211
faulty
Connection
RGB-module
212
faulty
213
SD card missing
214
SD card unreadable
Connection to easy Care ter-
215
minal faulty
216
Voltage varies, please check
No voice files on the SD
217
card, pleas check.
218
Connection DALI-unit faulty.
Connection rubinColl unit
219
faulty.
Quicktest Sensortolerance
226
OK
Quicktest Sensortolerance
227
error
Connection Bluetooth
230
module faulty
231
No display
ERROR MESSAGES
Description
Frequency detection failed. No mains
faulty
voltage.
INFORMATION MESSAGES
Description
The content of the aquaCool canister is
sufficient for another 2.5 hours of operation
with a spraying time of 6 seconds each.
Communication between control and
module/interior control panel
interrupted.
aquaCool canister empty.
System has run out of scent.
Condensate canister of air-conditioning
unit full.
Button cell (CR-2032) of the control board
discharged.
Communication between control and
"preSelection" control panel has been
interrupted.
No SD card in the audio module.
SD card defective, incompatible content.
Communication between control and
easyCare terminal has been interrupted.
Power supply to the mainboard varies
No voice files on the SD card found.
DALI-unit - CAN-BUS connection lost.
Driver LED booster. CAN-BUS connec-
tion lost.
Sensor Quicktest log entry - No display
appears - Message will be stored directly
in the event log (service menu).
Communication between control and
bluetooth module has been interrupted.
Internal notification - stored in the error log
(service technician information).
Remedy
Check mainboard connector X6/E6.
Remedy
Replace the empty aquaCool canister with a full one.
Do not replace aquaCool with any other liquid.
Check / replace the patch cable. Acknowledge the
has been
message by pressing START. If the fault persists,
contact your Customer Service.
Replace the aquaCool canister with a full one.
See chapter: Refilling Aroma and aquacool
Replace the Aroma tin.
See chapter: Refilling Aroma and aquacool
Empty the condensate canister of the air-conditioning
unit, acknowledge the message by pressing START.
Replace the button cell (CR-2032).
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your Customer Service.
Insert an original SD card. See chapter: Recording to
an SD card/Removing the SD card
Insert a new original SD card. Acknowledge the
message by pressing START. See chapter: Recording
to an SD card/Removing the SD card. If the fault
persists, contact your Customer Service.
Check
cable
connections
Acknowledge the message by pressing START. If the
fault persists, contact your Customer Service.
Check power supply to the mainboard.
Rebuild voice folder on the SD card. If necessary
replace original SD card.
Contact your customer service.
Contact your customer service.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your Customer Service.
O p e r a t i n g I n s t r u c t i o n s | megaSun 7900
and
power
supply.
-
-
α
57