System messages

After the error has been eliminated, all error messages must be acknowledged by pressing START on the interior control panel.
No.
Status message
01
Excess temperature bimetal
02
Maximum tanning time!
Excess temperature exhaust
03
fan, please check
Connection fan speed con-
04
trol faulty
Canopy pane open, please
08
close
Side pane open, please
09
close
Bench / bench pane open,
10
please close
Excess temperature bimetal
11
x-tra Tan
KBL7
Hardware
12
Input-Controller
Maximum write cycle flash
13
memory reached
Error! SD card read error
14
(CRC fault)
Error! no access to the SD
15
card
Parameter
17
found, please connect and
restart
Parameter storage no valid
18
serial number
CAN-BUS: Interior display
19
V1 is incompatible
CAN-BUS: preSelection dis-
20
play V1 is incompatible
CAN-BUS: audio module full
21
V1 is incompatible
CAN-BUS: RGB module V1
22
ist incompatible
Parameter
23
error
24
Parameter storage read error
Frequency detection: detec-
25
tion failed!
56
O p e r a t i n g I n s t r u c t i o n s | megaSun 7900
Description
Bimetal switch triggers.
Enabling signal from coin-box system
comes in longer than the time value
approved under "Maximum tanning time"
(voltage remains connected)
Bimetal switch in the fan triggers.
Faulty communication between Mainboard
and fan-speed control.
Contact of the canopy pane has triggered.
Contact of the side pane has triggered.
Contact of the bench pane has triggered.
Bimetal switch in the shoulder tanner
triggers.
error
Mainboard defective.
Maximum write cycle flash memory
reached.
Update via SD card failed (CRC fault).
Update via SD card failed (access error).
storage
not
Parameter storage not found, please con-
nect and restart.
Parameter storage no valid serial number.
CAN-BUS operators incompatible.
storage
write
Parameter storage write error.
Parameter storage read error.
Frequency detection failed.
ERROR MESSAGES
α
Remedy
Check the air-intake/air-discharge system. Let the tan-
ning device cool down.
Disconnect from the coin-box system.
Make sure the fan runs freely. Check the air-intake/
air-discharge system. Let the tanning device cool down.
Check / replace the patch cable.
Close the canopy pane and check the contact.
Close the side pane and check the contact. If the fault
persists, contact your Customer Service.
Close the bench / bench pane and check the contact.
Check the ventilation system of the shoulder tanner.
Let the tanning device cool down. If the fault cannot be
eliminated in this way, contact your Customer Service.
Contact your Customer Service.
Contact your Customer Service.
SD card check / replace.
SD card check / replace
Check connector parameter storage. If necessary
replace parameter storage.
Contact your Customer Service.
Use CAN-BUS operaters V2.
Check connector parameter storage. If necessary
replace parameter storage.
Check connector parameter storage. If necessary
replace parameter storage.
Restart the controller. Contact your Customer Service
after the third unsuccessful restart.