TESTING THE PROTECTIVE PANE-SWITCHES
Excessive UV radiation
Operating the tanning device with defective filter
panes can result in serious injury to skin and eyes.
• Test the protective pane-switches with each
removing of the filter panes.
Press the switch. When a clicking sound is heard,
and the switch automatically return, the system is
functional.
DANGER
Canopy
Side
Tubes
4
• When installing the tubes, make sure that the
tube inscription is visible. If it is installed in
a different position, there will be no tanning
effect.
• After new tubes have been installed, the
operating hours of the tubes must be reset in
the service menu.
REMOVING TUBE
TUBE REPLACEMENT IN THE BENCH PART
⇒
Open the bench pane.
If the tanning device is equipped with an air-
⑮
conditioning unit, remove the ducting pane.
⇒
Remove the tubes.
O p e r a t i n g I n s t r u c t i o n s | megaSun 7900
↵
ⓑ
ⓐ
90
0
⑮
α
45