Vt/Port Traps - ADTRAN 1200287L1 User Manual

Adtran, inc. modem user manual
Table of Contents

Advertisement

Chapter 3. Configuration

VT/Port Traps

Trap
LOS
CAIS
LAIS
XCV
Failure
VT-LOP
VT-AIS
3-30
If enabled, the unit issues a trap when...
(T1/E1 Loss of Signal)
The unit has lost the receive signal on a T1/E1.
(Carrier Side AIS)
The T1 is receiving all ones from the STS side
of the network.
(Loop Side AIS)
The T1 is receiving all ones from the DSX-1
interface.
(T1/E1 Excessive Code Violations)
The controller card is receiving excessive code
violations, exceeding the threshold set by the
user (see XCV Threshold on page 3-12).
(VT Path Loss of Pointer)
When the unit fails to find a valid VT pointer. A
VT LOP defect is declared when either a valid
pointer is not detected in eight consecutive VT
superframes, or when eight consecutive VT
superframes are detected with the NDF set to
"1001" without a valid concatenation indicator. A
VT LOP failure is declared when the VT LOP
defect persists for 2.5 +/- 0.5 seconds.
(VT Path Alarm Indication Signal)
The unit is receiving a VT path alarm indication
signal. VT-Path AIS is specified as all ones in
bytes V1, V2, V3, and V4, as well as all ones in
the entire VT synchronous payload envelope. A
VT-Path AIS failure is declared when the VT-
Path AIS defect persists for 2.5 +/- 0.5 seconds.