CLEI: M3CUX30B_ _
Product P/N: 1186004F1
D
ESCRIPTION
The ADTRAN
card, which generates a timing signal synchro-
CLK
nized to either of two external BITS clock refer-
ACT
1186004
ences. If both BITS clock references fail, the Clock
Card meets Sonet Minimum Clock (SMC)
holdover requirements to produce the clock
reference. This signal is used by the MX2820 to
synchronize its STS-1 transmit. Two Clock Cards
provide 1-to-1 redundancy in the MX2820 system.
F
EATURES
The MX2820 Clock Card has the following features:
Provides a redundant SMC source with clock holdover to the
MX2820 STS-1 Multiplexer
Communicates to the redundant Clock Card though an
asynchronous data link directly between the two cards
Provides another direct link to the redundant card for
protection management
Maintains full duplex link to the System Controller Unit (SCU)
for management, alarm notification, and card provisioning
Displays status using a single front panel LED, labeled
Supports downloading of FLASH program data to the active
and protection card simultaneously or individually
Meets NEBS Level 3 requirements
Interfaces to backplane through a 24-pin Future Bus connector
Supports TL1 and SNMP
I
NSTALLATION
After unpacking the unit, inspect it for damage. If damage is
found, file a claim with the carrier and then contact Customer
Service. For more information, refer to the warranty.
This module occupies a Clock Card slot in the MX2820 chassis.
Follow these steps to install the Clock Card:
1. Pull the ejector tab into the down position.
2. Gently but firmly push the Clock Card into the selected
Clock Card slot.
3. Apply thumb pressure at the top and at the bottom of the
unit to ensure a good seat of the Clock Card into the
backplane connector.
4. Push the ejector tab up and closed against the front panel.
Upon installation, the Clock Card begins a self-test. When the
self-test is complete, the LEDs indicate the current status of the
hardware.
Clock Card
MX2820 Clock Card is a plug-in
®
MX2820
LED Status for Active MX2820 Clock Card
The following table provides the LED indications for the active
card in a redundant pair.
Label
Status
ACT
Green
Yellow
2
Yellow Flashing
Red
2
Red Flashing Slow
2
Red Flashing Fast
LED Status for Standby MX2820 Clock Card
The following table provides the LED indications for the standby
card in a redundant pair.
Label
Status
ACT
Green
Yellow
Red
O
PERATIONAL
ACT
Operates from –42 VDC to –56 VDC input voltage power feeds
Operational temperature range of 0°C to +50°C with fans
Storage –40°C to +85°C; Relative humidity to 95 percent,
noncondensing
S
AFETY AND
Refer to the Safety and Regulatory Compliance Notice for this
product (P/N 61186004F1-17) for detailed safety and regulatory
information.
Consultez l'avis sur la sécurité et la conformité à la réglemen-
tation pour ce produit (61186004F1‐17) pour obtenir des
renseignements détaillés sur la sécurité et la réglementation.
Ausführliche Sicherheits- und regulatorische Informationen sind
in der Konformitätserklärung zur Sicherheit und Einhaltung von
Normen zu diesem Produkt (61186004F1‐17) aufgeführt.
jobAid
Issue Date: November 2011
Document P/N: 61186004F1-22A
Description
Normal (all OK)
Software update in progress
Console open
Major or Minor alarm in progress
Clock Card has failed
Critical alarm in progress
Description
Normal (all OK)
Software update in progress
Self-test failure
S
PECIFICATIONS
R
C
EGULATORY
OMPLIANCE
1

Advertisement

loading

Summary of Contents for ADTRAN MX2820

  • Page 1 Service. For more information, refer to the warranty. renseignements détaillés sur la sécurité et la réglementation. This module occupies a Clock Card slot in the MX2820 chassis. Ausführliche Sicherheits- und regulatorische Informationen sind Follow these steps to install the Clock Card: in der Konformitätserklärung zur Sicherheit und Einhaltung von...
  • Page 2 MX2820 Clock Card provisioning is available through the MX2820 System menu by selecting . Type C, and press ENTER Access Modules to access the active MX2820 Clock Card. The menu tree below illustrates the options and default settings for the MX2820 Clock Card. CLEI Code Part Number Serial Number 1.