: Pyxis400 DISASS'Y SOP
Document No.
Pull out Backlight cable
Operation Name :
Glove Requirements: Half-finger gloves
Note: If finding anything uncommon, notice foreman or assistant at once.
Fixture list (Specification)
Tabulator:
Xin-Xin Chen
Standard Operation Procedure
Hook
Fig. 1
Tear off the
acetate tape
Auditor : Ethan Lai
Ver. :
Steps:
1. Pull out Backlight cable from the hooks, then
pull out it vertically from the top of connector
on M/B (Fig. 1, 2).
 Be careful not to make the pin heads of the
connector are crooked.
 Tear off the acetate tape (Fig. 2).
Qty.
Fixture list (Specification)
Issue Department:
Station :
1.00
2017/5/23
Date
:
Fig. 2
NPSU-PPE