: Pyxis400 DISASS'Y SOP
Document No.
Take out Top Vent
Operation Name :
Glove Requirements: Half-finger gloves
2
Note: If finding anything uncommon, notice foreman or assistant at once.
Fixture list (Specification)
Electric Screwdriver (S-4000MS)
Bits Type: T15,φ=5mm,L=60mm
Tabulator:
Xin-Xin Chen
Standard Operation Procedure
3
Qty.
1
1
Auditor : Ethan Lai
Ver. :
Steps:
1. Unscrew (Torx Pin-Head × 5) all joints of Top
Vent (Fig. 1).
Torsion: 4.0 ± 1.0 kgf.cm
Take the screwdriver vertically to the screw
holes.
2. Follow the direction of the red arrow to take
out Top Vent (Fig. 1).
Take out Top Vent moderately to prevent
damaging it.
1
4
Fixture list (Specification)
Issue Department:
Station :
1.00
2017/5/23
Date
:
NPSU-PPE
11(1/1)
5
Fig. 1
Qty.