: Pyxis400 DISASS'Y SOP
Document No.
Take out Vesa Mount
Operation Name :
Glove Requirements: Half-finger gloves
3
4
1
Note: If finding anything uncommon, notice foreman or assistant at once.
Fixture list (Specification)
Electric Screwdriver (S-6000MS)
Bits Type: T15,φ=5mm,L=60mm
Tabulator:
Xin-Xin Chen
Standard Operation Procedure
5
图一
2
Fig. 1
Fig. 2
Qty.
1
1
Auditor : Ethan Lai
Ver. :
Steps:
1. Unscrew (× 5) all joints of Vesa Mount
illustrated as Fig. 1.
Torsion: 6.0 ± 1.0 kgf.cm
Take the screwdriver vertically to the screw
holes.
Put the screws into the material box.
2. Follow the angle of the red line to take out
Vesa Mount (Fig. 2).
Fixture list (Specification)
Issue Department:
Station :
1.00
2017/5/23
Date
:
NPSU-PPE
8(1/1)
Qty.