Appendix C: Configuring The Rs-232 Port For Use; Obtaining Communications; Configuration Options; Rs-232 Port Configuration - Crestron Isys TPS-4500 Operation Manual

12 inch tilt and lectern touchpanels
Hide thumbs Also See for Isys TPS-4500:
Table of Contents

Advertisement

12 Inch Tilt/Lectern Touchpanels

Appendix C: Configuring the RS-232 Port for Use

44 • 12 Inch Tilt/Lectern Touchpanels: TPS-4500 & TPS-4500L
To configure the RS-232 port of the TPS-4500/L, a local PC that contains a Crestron
Viewport is required. The Viewport is one of the development tools that is part of
Crestron SIMPL Windows or VT Pro-e software.

Obtaining Communications

Refer to "Communication Settings" on page 32 for detailed instructions on
connecting a PC to the touchpanel.

Configuration Options

There are several RS-232 communication options (at the time of this printing, these
were available):
CONSOLE – console active on RS-232 port. Use to load programs,
firmware, or to set configuration. This is the default. Use this
configuration if no other option is appropriate.
CONTROL – activates special control mode. Use for control by non-
Crestron device or within a non-Crestron control system. Refer to
"Appendix A: RS-232 Protocol" on page 41. For details.
TOUCHOUT – touchscreen output sent to RS-232 port. Use for serial
mouse control or Telestrator output. Directly connect computer or
Telestrator box to RS-232 port on TPS-4500/L (i.e., touch screen
output). For example, use when an RGB window with tablet overlay on
the TPS panel acts as a serial mouse controller for a PC. In this case,
use the Crestron Serial Mouse Control Driver (tpad.exe), which can be
downloaded from the Downloads | Software Updates section of the
Crestron website (www.crestron.com). Another use is with the
Pointmaker
Guide, which can be downloaded from the Downloads | Product
Manuals section of the Crestron website (www.crestron.com).
MOUSE – RS-232 port used for mouse input. For use with a
Microsoft
Compatible Serial Mouse as a pointing device on the
TPS-4500/L. Also known as "Touch the PC".
EXT_TOUCH – RS-232 port used for external touch screen input (i.e.,
SMART Matisse Overlay or Microtouch Display).

RS-232 Port Configuration

After establishing communication, the RS-232 can now be configured for
communication with an option. Complete the following steps in the order provided.
1. From the "TPS>" prompt, enter the following command:
rs232 ?
Crestron TPS-4500 & TPS-4500L
telestrator. For details, refer to the Telestrator Integration
Operations Guide - DOC. 5891A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isys tps-4500l

Table of Contents