12 Inch Lectern/Wall Mounted Touchpanel
Appendix C: Configuring the RS-232 Port for Use
48 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L
To configure the RS-232 port of the TPS-5000L, a local PC that contains a Crestron
Viewport is required. The Viewport is one of the development tools that is part of
®
Crestron SIMPL
Windows
Obtaining Communications
Refer to "Communication Settings" on page 36 for detailed instructions on
connecting a PC to the touchpanel.
Configuration Options
There are several RS-232 communication options (at the time of this printing, these
were available):
•
CONSOLE – console active on RS-232 port. Use to load programs,
firmware, or to set configuration. This is the default. Use this
configuration if no other option is appropriate.
•
CONTROL – activates special control mode. Use for control by non-
Crestron device or within a non-Crestron control system. Refer to
"Appendix A: RS-232 Protocol" on page 45. For details.
•
TOUCHOUT – touchscreen output sent to RS-232 port. Use for serial
mouse control or Telestrator output. Directly connect computer or
Telestrator box to RS-232 port on TPS-5000L (i.e., touch screen
output). For example, use when an RGB window with tablet overlay on
the TPS panel acts as a serial mouse controller for a PC. In this case,
use the Crestron Serial Mouse Control Driver (tpad.exe), which can be
downloaded from the Downloads | Software Updates section of the
Crestron website (www.crestron.com). Another use is with the
Pointmaker
Guide, which can be downloaded from the Downloads | Product
Manuals section of the Crestron website (www.crestron.com).
•
MOUSE – RS-232 port used for mouse input. For use with a
Microsoft
Compatible Serial Mouse as a pointing device on the
TPS-5000L. Also known as "Touch the PC".
•
EXT_TOUCH – RS-232 port used for external touch screen input (i.e.,
SMART Matisse Overlay or Microtouch Display).
RS-232 Port Configuration
After establishing communication, the RS-232 can now be configured for
communication with an option. Complete the following steps in the order provided.
1. From the "TPS>" prompt, enter the following command:
rs232 ?
2. The TPS-5000L responds with the following:
RS232MODE [CONSOLE|CONTROL|RF|TOUCHOUT|MOUSE|EXT_TOUCH]
CONSOLE – console active on RS232 port
Crestron Isys™ TPS-5000L
®
or VisionTools
Pro-e (VT Pro-e) software.
telestrator. For details, refer to the Telestrator Integration
Operations Guide - DOC. 5783A