12 Inch Tilt/Lectern Touchpanels
32 • 12 Inch Tilt/Lectern Touchpanels: TPS-4500 & TPS-4500L
Communication Settings
Connection of a PC to the TPS-4500/L touchpanel can be direct via the RS-232 port
on the touchpanel or through a control system (Cresnet). Both methods of connection
provide setup for RS-232 communication.
To prepare the TPS-4500/L for uploading or upgrading, refer to the following figure
for a typical connection diagram.
Typical Connection Diagram when Uploading a Project
To prepare the TPS-4500/L for uploading or upgrading directly from a PC, refer to
the following figure. Connect the RS-232 port of the computer directly to the RS-232
port of the touchpanel. Refer to page 16 for RS-232 cable information.
NOTE: Directly connecting to the touchpanel over RS-232 provides a faster
transmission speed than Cresnet.
Typical Connection Diagram when Uploading a Project Directly to the Touchpanel
NOTE: For cable pinouts, refer to "RS-232" on page 16.
1. Open the Crestron Viewport.
Either launch the stand-alone version of Viewport, or start SIMP Windows,
and from the menu bar, select Tools | Viewport.
2. Refer to the following figure. From the Viewport menu, select Setup |
Communications settings (alternatively, press Alt+D) to open the "Port
Settings" window.
Crestron TPS-4500 & TPS-4500L
Operations Guide - DOC. 5891A