Diagnostic Tools
Table 3-4: POST Error Messages
Error code
Error message
0212
Keyboard Controller Failed *
0220
Monitor type does not match
CMOS - Run SETUP
0250
System battery is dead -
Replace and run SETUP
0251
System CMOS checksum bad
- Default configuration used
0260
System timer error *
0270
Real time clock error *
0271
Check date and time settings
02D0
System cache error - Cache
disabled *
Invalid System Configuration
Data
3-14
All manuals and user guides at all-guides.com
continued
Description/corrective action
Keyboard controller failed test.
The attached monitor cannot be correctly identified in by Setup.
Run Setup and check if the monitor type is correctly identified.
The CMOS clock battery indicator shows the system battery is
dead.
1.
Replace the system battery following the procedures on
page 3-42.
2.
Run Setup to reconfigure the system.
The settings in the Setup Utility have been corrupted or modified
incorrectly, perhaps by an application program that changes data
stored in CMOS.
You can either:
Load the system default values following the procedures on
page 3-11.
Access Setup and enter your own custom values.
If the error persists, check the system battery or contact your HP
Customer Support provider.
The timer test failed. Requires repair of the system board.
Real-Time Clock (RTC) fails BIOS hardware test. May require
board repair.
BIOS found date or time out of range and reset the RTC. May
require setting legal date (1991-2099).
Access Setup and check the values in the System Time and
System Date fields of the Main menu.
RAM cache failed and BIOS disabled the cache.
Problem with the CMOS data.
You can do any of the following:
Load the system default values following the procedures on
page 3-11.
Access Setup and enter your own custom values.
Clear the CMOS memory then restart the server. For
instructions, refer to the "Clearing CMOS" section on
page 3-11.
If the error persists, check the system battery or contact your HP
Customer Support provider.
HP ProLiant DL145 Generation 2 Server Maintenance and Service Guide