System will not passively arm until it is remotely armed and then disarmed:
Are the door inputs connected? Is the H1/6 blue wire connected to the door trigger wire in the
vehicle? Either the H1/5 green or the H1/7 violet should be used instead. (See wiring diagrams.)
Door input does not respond with the progressive trigger, but with immediate full alarm:
Does the Status LED indicate that the trigger was caused by the shock sensor? (See Diagnostics
section of this guide.) The shock sensor, if set to extreme sensitivity, may be detecting the door
unlatching before the door switch sends its signal. Reducing the sensitivity can solve this
problem.
The override switch doesn't work.
Is it plugged into the correct socket? See Plug-In LED and Override Switch section of this guide.
Status LED doesn't work.
Is it plugged in? (See Plug-In LED and Override Switch section of this guide.) Is the LED
plugged into the correct socket?
Door locks operate backwards.
This unit has easily-reversed lock/unlock outputs. Recheck wire connections to see if you have
reversed these.

Remote Start Troubleshooting

The remote start will not activate.
Check the harnesses and their connections. Make sure that the harnesses are completely plugged
into the remote start module. Make sure there are good connections to the vehicle wiring.
Check voltage and fuses. Use a meter to check for voltage between the red wire in the 5-pin
ribbon harness and the black ground wire. If you have less than battery voltage, check the 3A
and both 30A fuses on the relay satellite. Also make sure that the ground wire connects to a good
chassis ground point.
Check diagnostics. The diagnostics will tell you which shutdown is active or not connected.
The remote start will activate, but the starter never engages.
Check for voltage on the purple starter wire two seconds after the remote start becomes active.
If there is voltage present, skip to Step 4. If there is not voltage present, advance to Step 2.
Check the 30A fuses.
Check diagnostics. If the gray/black wire is detecting ground upon activation, the starter will
not crank.
Make sure the purple starter wire is connected on the starter side of the starter kill/anti-grind relay.
40