Menu #2 - Advanced Features

2-1 SIREN OUTPUT CONSTANT/PULSED: The system can be programmed to output pulses
instead of a continuous output when the system is triggered. This is useful to honk the factory horn
in applications where a siren is undesirable. Remember that the unit is only capable of supplying 1
amp of current. A relay will be required to interface with most factory horn systems.
2-2 SIREN DURATION 30/60 SECONDS: It is possible to program the unit to sound for
30 or 60 seconds during the triggered sequence. Some states have laws regulating how long
a security system can sound. When using the Pro Security Programmer, the siren can be
programmed to sound for any length of time from 1 second to 180 seconds.
2-3 FALSE ALARM PREVENTION CIRCUITRY ON/OFF: False alarm prevention circuitry stops
repeated triggering of the same zone. If one zone is triggered three times in one hour, that zone is
bypassed for one hour, starting from the time of the third trigger. During that hour, if the system
sees a trigger on that zone again, the system resets the one hour timer. If one hour passes and the
zone has not triggered again, the zone is activated and can trigger the system again. False alarm
prevention circuitry only monitors sensor inputs, and does not bypass the door trigger or the
ignition trigger at any time. If the false alarm prevention circuitry is turned off, the system will
respond to repeated triggers on the sensor inputs and will do so indefinitely. Some states have laws
regulating how many times a security system can trigger before it is considered a nuisance and the
vehicle is towed away.
2-4 PROGRESSIVE DOOR TRIGGER ON/OFF: The system responds to a door trigger input with
a progressive response. When the door is opened with the system armed, the siren will chirp 10
times prior to the full triggered sequence. The door trigger is still treated as an instant trigger and
closing the door quickly will not prevent full triggered sequence from occurring. If the progressive
door trigger is programmed off, the full siren output will occur the moment the door is opened.
2-5 OVERRIDE SWITCH PULSE COUNT 1 TO 5 PULSES: The system can be programmed to
count the number of presses of the override switch before disarming the security system. The factory
default setting is one pulse. The unit can also be set for two to five pulses.
Hidden Switch option: For added security, the GRAY wire on the two-pin override switch plug can
be connected to any switch in the vehicle that provides a positive (+) momentary pulse.
2-6 OPEN ZONE NOTIFICATION CHIRP ON/OFF: When programmed on, any active zone
input to the system during arming will generate a open zone notification chirp. When programmed
OFF, no open zone notification chirps will be generated if any zone is active during arming.
28