Cisco ASR 1002 Router Overview and Installation
The power supplies are installed into the rear of the chassis and are hot pluggable. The Cisco ASR 1002
Router supports up to 588 W input power from an infrastructure standpoint (cooling capacity, midplane
and power distribution) but initial power supply development limit is up to 470 W output (AC and DC
Input).
AC Power Supply for Cisco ASR 1002 Router
The AC power supply input inlet is an IEC connector with AC switch and the current rating on the
connector and switch is 10 Amps. The AC power supply is secured into the chassis with two captive
screws mounted on the faceplate.
Table 8-2
Table 8-2
Cisco ASR 1002 Router AC Power Supply LEDs
LED Label
LED
INPUT OK
Power supply activity
FAN OK
Power supply fan activity
A bi-color LED indicates
fan status.
OUTPUT FAIL
Power supply activity
Figure 8-6
Figure 8-6
OL-13208-09
describes the AC power supply LEDs on the Cisco ASR 1002 Router.
Color
Green
None
Green
Red
Red
shows the AC Power Supply for the Cisco ASR 1002 Router.
AC Power Supply for the Cisco ASR 1002 Router
1
2
3
4
OUTPUT INPUT
FAN
FAIL
OK
OK
0
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
8
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
Description
LED is green and signals that the AC power supply input
voltage is greater than 85 V.
If LED is not lighted, the AC input voltage is less than 70
V or the power supply is turned off. For an AC input
voltage between 70 V and 85 V the INPUT OK LED can
be either on, off, or flashing
The LED is illuminated green when all fans are
operational.
The LED is illuminated red when a fan failure is detected.
LED is red. It is off to signal that the DC output voltages
are within the normal operating range. Output voltage
between the minimum and maximum limits will not
create an output fail alarm and output voltages below the
minimum or above the maximum will create an output fail
alarm.
5
6
Cisco ASR 1002 Router Description
OUTPUT INPUT
FAN
FAIL
OK
OK
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
1
7
8-7