5.2.8.4 Constant cosphi
Inverter can feed in a fixed reactive power to grid. Users can set the power
factor(cosphi) in Constant cosphi page.
► Constant cosphi
Cosphi (P)
Constant Q
Q(V)
5.2.8.5 Cosphi (P)
Cosphi (P) is a function that inverter will feed in reactive power when its output
active power reach the setting values. For country Italy MV and Italy LV, users
can set lock-in voltage and lock-out voltage to assign the operation interval.
When grid voltage reach the lock-in voltage(V lock-in), inverter will enable
cosphi (P) function automatically and disabled it when grid voltage reach lock-out
voltage(V lock-out).
Constant cosphi
Cosphi (P)
►
Constant Q
Q(V)
Figure 5-23 : Constant cosphi page
Figure 5-24 : Cosphi (P) page
cosφ
Q upper
Q lower
P lower
Figure 5-25 : Cosphi (P) curve