9 Technical Data - Delta RPI Series Operation And Installation Manual

Grid-tie transformerless solar inverter
Hide thumbs Also See for RPI Series:
Table of Contents

Advertisement

Technical Data
9 Technical Data
Model
Enclosure
Operating temperature
Operating Altitude
Relative humidity
Environmental category
Protection degree
Pollution degree
Overvoltage category
Maximum backfeed
current to the array
Galvanic isolation
Safety class
Weight
Dimensions(W*H*D)
Connectors
Maximum input power
Rated power
Recommended PV power
Nominal voltage
Operating voltage
Startup voltage
Start up power
MPP tracker
Absolute maximum voltage
* The max withstand voltage is 1100Vdc. (inverter stop output when input is over 1000Vdc)
About 1000Vdc above application, please refer to appendix.
GENERAL
Powder coated aluminum
-25~60℃, full power up to 40℃
Full power up to 50°C @VDC 600V, COSØ=1
(Please refer to Figure 9-1 to 9-3.)
0% – 100% non-condensing.
Outdoor, wet locations
IP65 (Electronics)
AC output :III, DC Input :II
Class I metal enclosure with protective earth
612 × 740 × 278mm
Weather resistant connectors
DC INPUT (Solar side)
200Vdc – 1000 Vdc
Parallel inputs: 1 MPP tracker
Separate inputs: 2 MPP trackers
64
RPI M50A
2000m
II
0
NO
74kg
58kW
52.5kW
≦ 63kW
600Vdc
> 250 Vdc
40W
1100V *