Pentair Pool Products CC50 Owner's Manual page 4

Clean & clear cartridge filter
Hide thumbs Also See for Pool Products CC50:
Table of Contents

Advertisement

Available languages

Available languages

THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK
RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED.
PRESSURIZED AIR CAN CAUSE THE LID TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR
PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
2. Be certain the O-ring is in position in the lower tank half. Place the filter lid over the lower tank half,
making sure it is fully and firmly seated on the tank half, see Figure 2.
3. Place lock ring over the tank lid, and centering the lock ring on the threads of the tank body. Turn the
lock ring clockwise until the safety latches click and the lock ring hits the stops on the body. DO
NOT ATTEMPT TO OVER-TIGHTEN THE LOCK RING AFTER LOCK RING HAS HIT THE
STOPS ON THE BODY.
4. Follow the System Restart Instructions in Section C.
C. SYSTEM RESTART INSTRUCTIONS
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK
RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED.
PRESSURIZED AIR CAN CAUSE THE LID TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR
PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
1. Open the High Flow™ manual air relief valve until it snaps into the full open position (this only
requires a quarter turn counterclockwise). Opening this valve rapidly releases air trapped in the filter.
2. Stand clear of the filter tank, then start the pump.
3. Close the High Flow™ manual air relief valve after a steady stream of water
appears.
4. The system is not working properly if either of the following conditions occur.
a. A solid stream of water does not appear within 30 seconds, after the
pump's inlet basket fills with water.
b. The pressure gauge indicates pressure before water outflow appears.
If either condition exists, shut off the pump immediately, open valves in the water
return line to relieve pressure, and clean the air relief valve, see Section F. Cleaning
the High Flow™ manual air relief valve. If the problem persists, call (800) 831-7133 for
assistance.
D. CLEANING THE FILTER
The following information should be read carefully since it outlines the proper manner of care and operation for your filter system.
As a result of following these instructions and taking the necessary preventative care, you can expect maximum efficiency and
life from your filter system.
Please heed all manufacturers' posted instructions, warnings and cautions when using Baquacil
Clean.
1. Turn the pump off, shut off any automatic controls to ensure that the system is not inadvertently started
during servicing.
P/N 178556