Drive Assembly Removal and
Installation,
(continued)
Before installing this product, read and follow
all warning notices and instructions on page
ii - iii.
To install the drive assembly onto the motor
assembly:
1. Be sure all electrical breakers and switches are
turned off before installing the drive.
2. Be sure that the gasket between the drive and
motor is in place. It is critical in keeping moisture
out of the drive and motor. Replace the gasket if
damaged. Do not reassemble with a damaged
or missing gasket.
3. Verify that the three (3) orange motor post caps
are in position before placing the drive on the
motor assembly.
4. Align the drive assembly with the motor adapter
and seat the drive on the motor assembly.
5. Secure and tighten the drive assembly with the
three (3) Phillips head screws.
6. Plug the keypad back into the drive.
7. Place the keypad in the desired orientation on
the drive and reattach the four (4) screws in the
corners of the drive.
Note: Ensure that the keypad cable is not being
pinched between the drive and keypad.
INTELLIFLO
VSF Variable Speed and Flow Pump Installation and User's Guide
®
KEYPAD
ASSEMBLY
KEYPAD
SCREWS (4X)
#10-24 X 1.75" PHILLIPS
HEAD SCREWS
DRIVE TO MOTOR (3X)
ORANGE MOTOR
POST CAPS (3X)
ADAPTER
CONNECTOR
Drive Assembly and Removal
FIRE and BURN HAZARD - The pump motor
may run at a high temperatures. To reduce the
risk of fire, do not allow leaves, debris, or foreign matter to collect
around the pump motor. To avoid burns when handling the motor, shut
off the motor and allow it to cool for 20 minutes before servicing. The
pump provides an automatic internal cutoff switch to protect the motor
from heat damage during operation.