Filter Operation - Pentair Pool Products CC50 Owner's Manual

Clean & clear cartridge filter
Hide thumbs Also See for Pool Products CC50:
Table of Contents

Advertisement

Available languages

Available languages

Risk of electrical shock or electrocution. Position the filter and High Flow™ manual air relief valve to safely direct water
drainage and purged air or water. Water discharged from an improperly positioned filter or valve can create an
electrical hazard that can cause severe personal injury as well as damage property.
5. When installing the High Flow™ manual air relief
valve use the O-ring only, there is no need for thread
sealing compounds. Position the filter to safely direct
water drainage. Rotate the valve to safely direct
purged air or water. Water discharged from an
improperly positioned filter or valve can create an
electrical hazard as well as damage property.
6. Make all plumbing connections in accordance with
local plumbing and building codes. Filter plumbing connections are provided with an O-ring seal. Use only
a silicone base lubricant on the O-rings. Do not use pipe joint compound, glue or solvent on the bulkhead
connections.
7. The base of this filter is provided with two (2) mounting bosses for the purpose of anchoring the filter to the
concrete.
8. The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this
amount, even when conducting hydrostatic pressure tests. Pressures above 50 psi can cause the lid to be
blown off, which can result in severe injury, death or property damage.
When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing
system, ensure that the Maximum Pressure that the filtration system will be subjected to DOES NOT EXCEED
THE MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM.
In most cases, the maximum pressure will be stated on each component of the system.
If doubt exists as to the pressure to which the system will be subjected, install an ASME approved automatic Pressure Relief
or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system.
SECTION II. FILTER OPERATION
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM
(e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND
BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT
IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW
THESE INSTRUCTIONS.
1. BEFORE REPOSITIONING VALVES AND BEFORE BEGINNING THE ASSEMBLY, DISASSEMBLY, OR ADJUSTMENT OF
THE LOCK RING OR ANY OTHER SERVICE OF THE CIRCULATING SYSTEM: (A) TURN THE PUMP OFF AND SHUT
OFF ANY AUTOMATIC CONTROLS TO ASSURE THE SYSTEM IS NOT INADVERTENTLY STARTED DURING THE
SERVICING; (B) OPEN AIR RELIEF VALVE; AND (C) WAIT UNTIL ALL PRESSURE IS RELIEVED -PRESSURE GAUGE
MUST READ ZERO (0).
2. WHENEVER INSTALLING THE FILTER LOCK RING, FOLLOW THE FILTER LOCK RING INSTALLATION
INSTRUCTIONS EXACTLY.
3. ONCE SERVICE ON THE CIRCULATING SYSTEM IS COMPLETE, FOLLOW SYSTEM RESTART INSTRUCTIONS
EXACTLY.
4. MAINTAIN CIRCULATION SYSTEM PROPERLY. REPLACE WORN OR DAMAGED PARTS IMMEDIATELY (e.g., lock
ring, pressure gauge, relief valve, O-rings, etc.)
5. BE SURE THAT THE FILTER IS PROPERLY MOUNTED AND POSITIONED ACCORDING TO THE INSTRUCTIONS
PROVIDED.
P/N 178556
WARNING
Model
CC50
CC75
CC100
CC150
CC200
WARNING
2
TABLE 1.
P/N
Size
Clearance Req.
160314
50 sq. ft.
160315
75 sq. ft.
160316
100 sq. ft.
160317
150 sq. ft.
160318
200 sq. ft.
Vertical
30 in.
39 in.
61 in.
76 in.
76 in.
Rev. D 6-26-09