MENU
Pump Menu: Thermal Mode
THERMAL MODE
The sensor for Thermal Mode is in the drive, on top of
the motor. This feature allows you to set a speed (450-
3450 RPM) or flow (20-140 GPM) that runs when the
IntelliFlo
VSF Variable Speed and Flow Pump goes
®
into Thermal Mode. The temperature level that you wish
Thermal Mode to start can also be set.
IMPORTANT: This feature is for protection of the pump.
Do not depend on the Thermal Mode feature for freeze
protection of the pool. Certain situations could cause
the pump to sense a different temperature than actual
air temperature.
Your automation systems air temperature sensor should
be used to sense actual temperature. For example, if
the pump is located indoors, the temperature of the
room does not indicate the outdoor temperature. The
pump does not sense the water temperature.
To access the Thermal Mode menu:
1. Check that the green power LED is on.
2. Press Menu.
3. Use the Down arrow to scroll to "Thermal Mode"
and press Select.
4. The factory default for Thermal Mode is
"Enabled". To disable Thermal Mode, press
Select to highlight "Enabled".
5. Press the Up arrow - "Disabled" is displayed.
6. Press Save to save.
ThermMode
1000
Set Speed
Setting the Thermal Mode Pump Speed
THERMAL MODE
INTELLIFLO
VSF Variable Speed and Flow Pump Installation and User's Guide
®
12:15p
RPM
Disabled/Enabled
Set Type
Set Speed/Flow
Pump Temperature
Thermal Mode Menu Options
To Set Thermal Mode Speed/Flow and Pump
Temperature:
Note: Thermal Mode features are only accessible if
Thermal Mode is "Enabled".
1. Use the Up or Down arrows to scroll to "Set
Type". Press Select.
2. Use the Up or Down arrow to choose between
"Speed" or "Flow". Press Save.
3. Use the Up or Down arrow to scroll to "Set
Speed/Flow". Press Select.
4. Use the Up or Down arrow to adjust the speed or
flow settings. Press Save.
5. Press the Down arrow. "Temperature" will
display. (This value will determine at what
temperature the pump will activate Thermal
Mode, default is 40° F/4.4° C).
6. Press Select to edit. Use the Up or Down arrow
to adjust the settings.
7. Press Save to save the temperature setting.
Note: To cancel any changes, press Back to exit
without saving.
8. Press Back to exit.
ThermMode
40
Pump Temperature
Setting the Thermal Mode Pump Temperature
Disabled / Enabled - Default: Enabled
Speed
Flow
Set Speed (450-3450 RPM) Default 1000 RPM
Set Flow (20-140 GPM) Default: 40 GPM
40° F - 50° F (4.4° C through 10° C) Default: 40° F (4.4° C)