Module Isolation; Overview - Canon SADDLE FINISHER K3 Service Manual

Table of Contents

Advertisement

CHAPTER 2 OPERATION OVERVIEW

11 MODULE ISOLATION

11.1.1 Overview

If an error occurs in one of the modules, the finisher system enables the module con-
cerned to be isolated and another to be operated. If an error related to a certain module oc-
curs, the module concerned can be isolated by turning off the corresponding DIPswitch bit
on the switch PCB provided in the saddle stitcher. The table below shows the units where
the module isolation applies and the conditions when the module is isolated.
Units where module isolation applies
SW971 No.
SW971-1
Punch Unit
-2
Tray A
-3
Inserter
-4
Folder
-5
Saddle stitcher unit
-6
Not used
This table shows the errors for which the module can be isolated in each unit.
Unit
Punch unit
Tray A
Inserter
Folder
Saddle stitcher
2-94
COPYRIGHT© 2001 CANON INC.
Unit
Power flow is stopped. Connection is detected, but operation is
prohibited. The position of the punch unit must be initialized
by the user.
Power flow is stopped. Position of tray A must be adjusted by
user. Tray A is used as a fixed tray.
Power flow is stopped. Connection is detected, but operation is
prohibited.
Power flow is stopped. Connection is detected, but operation is
prohibited.
Power flow is stopped. Connection is detected, but operation is
prohibited.
T02-1101-01
E590, E593, E594
E540
E515
E518
E5F0, E5F1, E5F2, E5F3, E5F4, E5F5, E5F6, E5F7, E5F8, E5F9
T02-1101-02
2000 2000 2000 2000
Condition when cut off
Error
CANON SADDLE FINISHER K3/K4 REV.0 MAR. 2001