LOCATION REQUIREMENTS

Explosion Hazard
Keep flammable materials and vapors,
such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm)
above the floor for a garage installation.
Failure to do so can result in death,
explosion, or fire.
You will need
A location that allows for proper exhaust in-
stallation. See "Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a
grounded electrical outlet located within
2 ft (61 cm) of either side of the dryer. See
"Electrical Requirements."
A sturdy floor to support the total weight
(dryer and load) of 200 lbs. (90.7 kg). The
combined weight of a companion appli-
ance should also be considered.
A level floor with a maximum slope of
1˝ (2.5 cm) under entire dryer.
Do not operate your dryer at temperatures
below 45°F (7°C). At lower temperatures, the
dryer might not shut off at the end of an auto-
matic cycle. Drying times can be extended.
The dryer must not be installed or stored in an
area where it will be exposed to water and/or
weather.
Check code requirements. Some codes limit,
or do not permit, installation of the dryer in
garages, closets, mobile homes or sleeping
quarters. Contact your local building inspec-
tor.
NOTE: No other fuel-burning appliance can
be installed in the same closet as a dryer.

INSTALLATION CLEARANCES

The location must be large enough to allow
the dryer door to open fully.

Dryer Dimensions

43 ½"
(110.5 cm)
*29 ¼"
(74.3 cm)
*Most installations require a minimum 5˝
(12.7 cm) clearance behind the dryer for the
exhaust vent with elbow. See "Venting Re-
quirements."
Installation spacing for recessed area or
closet installation
The following spacing dimensions are recom-
mended for this dryer. This dryer has been
tested for spacing of 0˝ (0 cm) clearance on
the sides and rear. Recommended spacing
should be considered for the following rea-
sons:
Additional spacing should be considered
for ease of installation and servicing.
Additional clearances might be required for
wall, door and floor moldings.
Additional spacing should be considered
on all sides of the dryer to reduce noise
transfer.
For closet installation, with a door, mini-
mum ventilation openings in the top and
bottom of the door are required. Louvered
doors with equivalent ventilation openings
are acceptable.
Companion appliance spacing should also
be considered.
2-2
"
14³⁄
16
(36cm)
29"
(73.6cm)