With the door properly closed, the ohm-
meter should indicate a closed circuit
(0–2 ohms).
If not, replace the door switch assem-
bly. See Figure 13, and Removing the
Front Panel/Drum Assembly.
TEST #3b Blower Motor (Dual Motor Model)
1.
Access the motor control electronics. See
Accessing & Removing the Electronic As-
semblies.
2.
Visually check the communication har-
ness. See Figure 16. The communication
harness is a three-wire harness that con-
nects between the two electronic control
assemblies. Make sure it is fully inserted
into both electronic controls.
3.
If the communication harness looks OK,
go to step 4.
4.
Visually check the wire harnesses con-
nected to the motor control electronic
assembly. Make sure they are clean and
fully inserted into the control.
If the connections look OK, go to step 5.
5.
Remove the MC2 blower motor electrical
connector from the blower motor elec-
tronic control.
6.
Measure the resistance between the fol-
lowing terminals on the connector: pins
1 to 3, 1 to 5 and 3 to 5. The resistance
should be between 55 and 65 ohms.
If the resistance looks OK, go to step 7.
If the resistance is much greater than
65 ohms, go to step 7.
If the resistance is much less than 55
ohms, replace the blower motor.
7.
Visually check the wire harness connec-
tion at the blower motor (See Accessing
the Blower Motor below).
If the connections look OK, check for
obstructions in the blower housing.
Make sure blower fan rotates freely.
If no obstructions are found, replace
the motor control electronic assembly.
Accessing the Blower Motor:
Follow the steps under Removing the Front
Panel/Drum Assembly. The blower motor is
located on top of the blower housing as shown
in Figure 10.
Figure 10.
TEST #4 Heater
This test is performed when either of the fol-
lowing situations occur:
Dryer does not heat
Heat will not shut off
This test checks the components making up
the heating circuit. The following items are
part of this system:
Harness/connection
Heater relay
Thermal cut-off
Thermal fuse
High limit thermostat
Gas burner assembly
Centrifugal switch
Exhaust thermistor
Machine control electronics. See ESD
information
Gas supply
6-25
Blower Motor
Blower Motor Location.