Location Requirements - Kenmore 110.70012 Series Use & Care Manual

Coin-operated commercial gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Location Requirements

You will need:
A location that allows for proper exhaust installation. A
gas dryer must be exhausted to the outdoors. See "Venting
Requirements."
A grounded electrical outlet located within 2 ft (610 mm)
of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support dryer and a total weight (dryer
and load) of 200 lbs. (90.7 kg). The combined weight of
a companion appliance should also be considered.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE:
No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Dryer Dimensions
43
/
"
3
8
(1102 mm)
*26"
29"
(660 mm)
(737 mm)
A
A. Small opening side-swing door
B. Large opening side-swing door
43
/
"
3
8
(1102 mm)
6
3
15
/
"
1
4
(387 mm)
43
3
/
"
8
(1102 mm)
*27
/
"
3
4
29"
(705 mm)
(737 mm)
B
22¾"
(578 mm)
43
/
"
3
8
(1102 mm)
*27
/ "
3
*26"
(660 mm)
43
/
"
3
8
(1102 mm)
*27
3
/
"
4
(705 mm)
Installation Spacing
18"*
(457 mm)
29"
1"
(25 mm)
(737 mm)
A
*Required spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part 280) or
the Canadian Manufactured Home Standard CAN/CSA-Z240 MH.
Metal exhaust system hardware, available for purchase.
For further information, please reference the "Assistance
or Service" section of the "Dryer User Instructions."
Special provisions must be made in mobile homes to
22¾"
introduce outside air into the dryer. The opening (such as
(578 mm)
a nearby window) should be at least twice as large as the
dryer exhaust opening.
13¾"
(349 mm)
*27
/
"
3
4
29"
(705 mm)
(737 mm)
A
22¾"
(578 mm)
/
43
3
"
8
(1102 mm)
*27
/
3
4
29"
(705 mm)
(737 mm)
C
C. Wide opening side-swing door
D. Wide opening hamper door
14" max.*
48 in.
(356 mm)
(310 cm )
24 in.
(155 cm )
1"*
27
1"
¾"
(705 mm)
(25 mm)
(25 mm)
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
29"
(737 mm)
B
13¾"
(349 mm)
"
29"
(737 mm)
D
3"*
(76 mm)
2
*
2
*
3"*
2
2
(76 mm)
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

110.70172 series

Table of Contents