Kenmore Oasis 110.67032600 Manual page 90

Electric & gas dryer
Table of Contents

Advertisement

TROUBLESHOOTING GUIDE
Some tests will require accessing components. See Figure 1 for component locations.
PROBLEM
NOTE: Possible Cause/Tests MUST be performed in the sequence shown for
each problem.
1. Supply connections. See TEST #1.
WON'T POWER UP.
(No response when
2. Check harness connections.
buttons are pressed.)
3. User interface assembly. See TEST #6.
1. If number display flashes, check to be sure the
door is completely shut, and press and hold down
WON'T START CYCLE
START for about 1 second.
WHEN START BUTTON
IS PRESSED.
2. See TEST #3a.
3. See TEST #7.
1. Check STOP button. See TEST #6.
WON'T SHUT OFF
2. User interface assembly. See TEST #6.
WHEN EXPECTED.
3. Moisture sensor. See TEST #5.
TROUBLESHOOTING TESTS
NOTE: These checks are done with the dryer
unplugged or disconnected from power.
TEST #1 Supply Connections
This test assumes that proper voltage is pres-
ent at the outlet.
1.
Unplug dryer or disconnect power.
2.
Remove the cover plate from the back of
the dryer. See Figure 3.
Cover
Plate
Remove
Screw
Figure 3.
Remove the cover plate.
3.
Check that the power cord is firmly con-
nected to the dryer's wire harness. See
Figure 4.
Wire Harness
Figure 4.
Power cord-to-wire harness connection.
POSSIBLE CAUSE / TEST
Power Cord
PROBLEM
CONTROL WON'T
ACCEPT SELECTIONS. User interface assembly. See TEST #6.
1. Heater. See TEST #4.
WON'T HEAT.
2. Check harness connections.
3. Check installation.
HEATS IN AIR CYCLE.
Heater. See TEST #4.
1. Check the dryness setting for auto cycles.
2. Check for full lint screen.
SHUTS OFF BEFORE
3. Check for clogged vent.
CLOTHES ARE DRY.
4. Moisture sensor. See TEST #5.
5. Dryness level adjust. See Adjusting
4.
Access the machine control electronics
without disconnecting any wiring to the
control board. See Accessing & Remov-
ing the Electronic Assemblies.
5.
With an ohmmeter, check for continuity
between the neutral (N) terminal of the
plug and P8-3 (white wire) on the ma-
chine control board. The left-hand side of
figure 5 shows the position of the neutral
terminal (N) on the power cord plug. Also
see Figure 17.
If there is continuity, go to step 6.
If there is no continuity, disconnect
the white wire of the harness from the
power cord at the location illustrated
in Figure 4. Test the continuity of the
power cord neutral wire as illustrated
in Figure 5. If an open circuit is found,
replace the power cord. Otherwise, go
to step 6.
Power Cord
Plug
L1
G
Figure 5.
6-22
POSSIBLE CAUSE / TEST
Customer-Focused Drying Modes.
N
COM
L1
N
G
Plug-to-terminal connections.