Advanced Administration

Copying a Serial table for Uploading to different TVM-RX03s

It may be necessary to copy the file sXXX.001 to other files named sXXX.002 through sXXX.016 in
order to upload the serial files to TVM-RX03 units on all ports of the TVM-1600.
For example, if you used tftp to get a serial file from a TVM-RX03 unit on port 1, your file will have a
.001 file extension. To send this file to a TVM-RX03 on port 16 it would need a file extension of .016.
1. Use the Copy command (FIG. 55) to copy the serial files to different extensions on the PC;
FIG. 55
Copying a serial file
2. Upon completion, a successful copy message will be displayed (FIG. 56). The copied file can be
uploaded (put) onto other RXs.
FIG. 56
Successful copy of serial file
3. To upload (put) this Serial file to a TVM-RX03 unit on port 16 of the TVM-1600 hub use the tftp
command with the new file sSonyLCD.016. The command is shown below;
4. Push enter to execute the command.

Command Line Commands

All administration and configuration should be performed from the TVM Web
Browser. Only if directed by AMX support should the command line be used.
Inappropriate use of the command line may result in misconfigurations.
The hub includes a serial console port and accepts some text based commands at that port – some of
these commands are described below.
In all cases the serial parser will accept any command beginning with the right letter, c and channel, for
example, are equivalent.

Select Channel

Selects the channel on the ports specified by the Port property, or if non zero, the port specified in the
command.

Restore Last Selected Channel

Selects the last channel (i.e. the one selected before the current selection) on the ports specified by the
Port property, or if non zero, the port specified in the command
38
copy sXXX.001 sXXX.016 <enter>
Where XXX is the file name of the Serial table (e.g. sSonyLCD.001) and .001 represents
the port number of the TVM-1600.
tftp –i 192.168.1.200 put sSonyLCD.016
c [channel] [port]