• Be careful not to overfire the appliance by leaving
the door open too long after the initial start-up.
A thermometer on the chimney connector and/or
appliance top helps.
• Replace worn, dried out (inflexible) gaskets.
• Have chimney regularly cleaned.
IN CASE OF A CHIMNEY FIRE:
• Have a well understood plan for evacuation and
a place outside for everyone to meet. Prepare to
evacuate to ensure everyone's safety.
• Close air control on appliance.
• Call local fire department. Have a fire extinguisher
handy. Contact local authorities for further infor-
mation on how to handle a chimney fire.
• After the chimney fire is out, clean and inspect
the chimney or chimney liner for stress and cracks
prior to lighting another fire. Also check combusti-
bles around the chimney and the roof.

7.4 CHIMNEY CLEANING

Both the chimney and the appliance must be inspected
and cleaned at least once a year.
For serious wood burners, chimney cleaning must be
done as needed to avoid chimney fires; the venting
systems for controlled combustion appliances may
need cleaning as often as once a month. These rates,
however, depend on the burning habits of the individ-
ual operating the appliance. For example, it is possible
to clog a solid fuel appliance chimney in a few days if
slow, smoldering fires are burned and the chimney is
cold. NOTE: Appliances burned consistently with-
out hot fires may result in significant creosote
accumulations in the chimney.
Certain items and considerations are important in
chimney cleaning:
• Proper tools should be used, including a brush
specifically designed for chimney cleaning.
• The chimney connector and dampers as well as the
chimney should be cleaned.
• The appliance's firebox and baffle system should
be cleaned if needed.
• The chimney should be inspected and repairs made
if needed, preferably by a qualified chimney sweep
or mason.

7.5 GLASS REPLACEMENT

WARNING
DO NOT USE SUBSTITUTE MATERIALS
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL
COOLED.
CARE MUST BE TAKEN WHEN REMOVING AND
DISPOSING OF ANY BROKEN DOOR GLASS OR
DAMAGED COMPONENTS. BE SURE TO VACUUM UP
ANY BROKEN GLASS FROM INSIDE THE APPLIANCE
BEFORE OPERATION.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO
NOT OPERATE APPLIANCE WITH GLASS REMOVED,
CRACKED, BROKEN OR SCRATCHED.
INSTALLATION:
REMOVE THE DOOR FROM THE STOVE AND
REMOVE THE GLASS RETAINER. POSITION THE
4 MM CERAMIC SCHOTT ROBAX GLASS IN THE
DOOR, MAKE SURE THAT THE GLASS GASKETING
WILL PROPERLY SEAL YOUR UNIT, AND REPLACE
THE RETAINER, IT SHOULD REST ON THE GAS-
KET NOT THE GLASS. TIGHTEN SECURELY, BUT
DO NOT WRENCH DOWN ON THE GLASS AS THIS
MAY CAUSE THE GLASS TO BREAK. REPLACEMENT
GLASS PART AS FOR UNIT.

7.5.1 SINGLE FACED

pos.
name
1
special bolt
2
bottom flat bar, left
3
bottom flat bar, right
4
special bolt
5
bush
6
hexagon bolt M4x10
7
sheet metal screw 4,2x19
8
angle, top
9
angle, bottom
10
glass
11
seal 4x20x930 mm
12
seal 19x9 L=2880 mm
13
seal 4x20x484 mm
14
door profile
53