Door Removal / Installation - Spartherm Varia M60h Installation And Operating Instructions Manual

Table of Contents

Advertisement

5.2 DOOR REMOVAL / INSTALLATION

WARNING
BURNING YOUR APPLIANCE WITH THE DOORS
OPEN OR AJAR CREATES A FIRE HAZARD THAT
MAY RESULT IN A HOUSE AND/OR CHIMNEY FIRE.
DO NOT STRIKE OR SLAM DOOR.
NEVER REMOVE THE DOOR WHEN THE APPLIANCE
IS HOT.
pos.
name
1
cage nut M6
2
hood sheet
3
hexagon bolt M6x12
4
hexagon nut M6
5
cheese head cap screw M5x8
6
cheese head cap screw M6x25
7
cheese head cap screw M6x10
8
cheese head cap screw M8x35
9
pulley
10
door frame sheet
11
guide bar, left
12
guide bar, right
13
door frame sheet, bottom
14
air guide sheet
single faced
Example shown: Varia M100h