  • Page 1 Installation and Operating Instructions Wood Fireplace Varia M60h / M80h / M100h · Varia Bh / B-FDh · Varia 2L-80h / 2R-80h · Varia 2L-100h / 2R-100h · Arte Bh · Arte 3RL60h / 3RL80h / 3RL100h · Arte U-50h-2016 / U-70h-2016 / U-90h-2016 Spartherm Feuerungstechnik GmbH Maschweg 38 ·...
  • Page 2 SAFETY INFORMATION WARNING WARNING HOT GLASS WILL CAUSE BURNS. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR DO NOT TOUCH GLASS UNTIL COOLED. EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. NEVER ALLOW CHILDREN TO TOUCH GLASS. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. Installation overview 4.4.4 Varia Bh 5.1.7 Varia 2R-80h 8. Replacements 4.4.5 Arte Bh 5.1.8 Varia 2L-100h 8.1 Varia M-60h 2. Introduction 4.4.6 Varia 2L-80h 5.1.9 Varia 2R-100h 8.2 Varia M-80h 2.1 Example of identification plate 4.4.7 Varia 2R-80h 5.1.10 Varia B-FDh 8.3 Varia M-100h 2.2 Dimensions...
  • Page 4: Installation Overview

    • material in a safe manner. As with all plastic bags, or clothing ignition. these are not toys and should be kept away from The Spartherm fireplaces have been tested and • Young children should be carefully supervised when children and infants.
  • Page 5: Example Of Identification Plate

    DO NOT OVERFIRE – IF HEATER OR CHIMNEY CONNECTOR EVITER DE SURCHAUFFER – SI LE FEU OU LA CHEMINÉE GLOWS, YOU ARE OVERFIRING. DEVIENT ROUGE, VOUS SURCHAUFFEZ. Spartherm – v1.1, 11. Apr. 2018 DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE...
  • Page 6: Dimensions

    2.2 DIMENSIONS 2.2.1 DIMENSIONS SINGLE FACED Varia M60h-P4 Varia M80h-P4 Varia M100h-P4 25 2/5" 33 1/4" 41 1/7" 4" 3 1/2" 3 1/2" 5 1/4" 4 5/6" 4 5/6" 22 4/5" 30 2/3" 38 1/2" 5 5/9" 5 5/6" 5 5/6"...
  • Page 7 2.2.2 DIMENSIONS SINGLE FACED Varia Bh-P4 Arte Bh-P4 38" 28" 5 7/8" 4 1/2" 5 5/8" 8 1/2" 39" 19 4/5" 5 1/5" 4" 15 1/6" 16 1/6" 2 1/5" 1 1/4" 3 5/8" 4 7/8" 6 3/4" 4" 13 2/5" 14 4/7"...
  • Page 8: Dimension Two Sided

    2.2.3 DIMENSION TWO SIDED Varia 2L-80h-P4 Varia 2L-100h-P4 Varia 2R-80h-P4 Varia 2R-100h-P4 4 1/2" 4 1/2" 28 2/9" 37 2/3" 8 1/5" 6 3/5" 6 1/2" 4 7/8" 12 2/3" 14 1/4" 5 4/6" 5 4/6" 13 1/2" 13 1/2" 8 1/4"...
  • Page 9: Dimension Double Sided

    2.2.4 DIMENSION DOUBLE SIDED Varia B-FDh-P4 41 1/3" 5 5/9" 2 1/2" 17" 6 7/9" 13 1/7" 2 1/5" 3 5/8" 7 7/8" 19 2/3" 26 1/7" 53 2/3" 5 1/8" 13 1/3" 5 5/6" 6" 26 2/9" 25 3/4" 13 3/7"...
  • Page 10: Dimension Three Sided

    2.2.5 DIMENSION THREE SIDED Arte 3RL60h-P4 Arte 3RLh80h-P4 Arte 3RL100h-P4 18 1/4" 26 1/7" 34" 3 1/2" 3 1/2" 3 5/8" 3 5/8" 3 2/3" 3 7/9" 18" 26" 33 7/9" 5 3/7" 5 3/7" 5 3/7" 13 1/3" 14 1/2" 16 1/2"...
  • Page 11 2.2.6 DIMENSION THREE SIDED Arte U-50h- Arte U-70h- Arte U-90h- 2016-P4 2016-P4 2016-P4 14 2/3" 14 2/3" 16 6/7" 3 2/5" 3 3/7" 3 3/7" 14 1/5" 14 1/5" 16 3/8" 3 1/7" 3 1/7" 3 1/7" 7 3/5" 8 8/9" 7 2/7"...
  • Page 12: Specification

    2.3 SPECIFICATION Fire chamber volume Minimum Power Maximum power Efficiency* Chimney type Unit weight ideal fuel size Varia M60h 2.53 ft 16500 BTU 31000 BTU >78% 8" 452 lbs 18" Varia M80h 3.5 ft 21500 BTU 40000 BTU >78% 8"...
  • Page 13: General Information

    We suggest that our woodburning hearth products 2.5 GENERAL INFORMATION be installed and serviced by professionals who are The chimney vent system used on your wood burning appliance should be designed with the least amount of certified in the U.S. by the National Fireplace restriction possible to enable the exhaust products to easily flow through it.
  • Page 14 Unlock transportation lock To unlock the transportation lock, open the cover. Then loosen the screw with the socket wrench. Turn the socket Once the fireplace has been dismantled unlock the conunterweights using a socket-wrench size 13. Remember to wrench to the left. Then close the cover. perform this operation before inserting the fireplace into the enclosure.
  • Page 15: Air System

    Ø150mm separate combustion air connector Ø150mm Example shown: Varia M80h is mandatory for: Varia M60h, Example shown: Varia Bh is mandatory for: Example shown: Arte U-90h is mandatory for: Arte U-50h M80h, M100h, 2L-80h, 2R-80h, 2L-100h, 2R-100h and...
  • Page 16: Connection Directly To The Unit

    2.6.1 CONNECTION DIRECTLY TO THE UNIT To connect the separate combustion air directly to the unit you need to have the separate combus- tion air connector Ø 6” (A # 1018173). Fix the connector directly to the unit. It can be oriented to the left side, right side or to the back.
  • Page 17: Door Opening For All Doors

    2.7 DOOR OPENING FOR ALL DOORS Closure valve If you decide to connect separate combustion air it is Use the “operational tool“ to open and close the door. mandatory to install a closure valve to prevent conden- sate formation and to prevent the room from becoming cold while the stove is not in use.
  • Page 18: Installation Planning

    MUST BE UNRESTRICTED WHILE APPLIANCE IS IN combustible mortar, creosote USE TO PREVENT ROOM AIR STARVATION WHICH Varia M60h 48" 16 5" 84" material deposits, blockage or other signs of deterioration. If...
  • Page 19: Placement

    You must finish the front side of the fireplace using a cement board. CAUTION! Spartherm recommends the use of one piece cement board in place of multiple in order to avoid cracks. > Screw the cement board on the frame.
  • Page 20: Frames

    A 20” x 12” (500mm x 300mm) minimum hearth exten- sion made of non combustible material is required. To prevent any burning embers falling between the fire- place and the hearth extension from coming into con- Varia M60h Varia M80h Varia M100h Varia Bh...
  • Page 21: Double Sided

    4.1.3 DOUBLE SIDED 4.2 DISTANCE COMBUSTIBLE MANTLE 4.3 FOUR SEASON ROOM Back side INSTALLATION The Varia B-FDh: Can be installed into a four seasons configuration. The four season´s configuration is not recommended, when installed in colder climates as some condensa- tion may occur.
  • Page 22: Varia M-60H

    4.4.1 VARIA M-60H 4.4.2 VARIA M-80H pos. name pos. name cheese head cap screw M5x8 door lock frame cheese head cap screw M5x8 slide frame door slide weight shaft sheet door...
  • Page 23: Varia M-100H

    4.4.3 VARIA M-100H 4.4.4 VARIA BH pos. name pos. name door lock door lock cheese head cap screw M5x8 cheese head cap screw M5x8 frame frame slide slide door door weight shaft sheet, left weight shaft sheet, right...
  • Page 24: Arte Bh

    4.4.5 ARTE BH 4.4.6 VARIA 2L-80H pos. name pos. name frame frame slide slide door door weight shaft sheet weight shaft sheet door lock clamp cheese head cap screw M5x8...
  • Page 25: 4.4.7 Varia 2R-80H

    4.4.7 VARIA 2R-80H 4.4.8 VARIA 2L-100H pos. name pos. name weight shaft sheet weight shaft sheet frame weight shaft sheet, inside slide frame door slide clamp door...
  • Page 26: Varia 2R-100H

    4.4.9 VARIA 2R-100H 4.4.10 VARIA B-FDH FRONT pos. name pos. name weight shaft sheet lever weight shaft sheet, inside cheese head cap screw M5x8 frame hood sheet slide slide door door weight shaft sheet, left weight shaft sheet, right cadre...
  • Page 27: Varia B-Fdh Back

    4.4.11 VARIA B-FDH BACK 4.4.12 ARTE 3RL-60H pos. name pos. name frame frame door slide, right slide, left door...
  • Page 28: Arte 3Rl-80H

    4.4.13 ARTE 3RL-80H 4.4.14 ARTE 3RL-100H pos. name pos. name frame frame slide, left slide, left slide, right slide, right door door...
  • Page 29: 12 4.4.15 Arte U-50H-2016

    4.4.15 ARTE U-50H-2016 4.4.16 ARTE U-70H-2016 pos. name pos. name frame frame slide, left slide, left slide, right slide, right door door...
  • Page 30: 13 4.4.17 Arte U-90H-2016

    4.4.17 ARTE U-90H-2016 pos. name frame slide, left slide, right door...
  • Page 31: Chimney Installation

    4.5 CHIMNEY INSTALLATION on the fireplace will help avoid the noise created • Cut and frame square holes in all floors, ceilings when the fireplace expands. This can be achieved and roof that the chimney will go through to pro- The table below shows the minimum height require- This fireplace is designed and approved for installation by having the chimney supported by the supports.
  • Page 32: Examples Of Typical Installations

    4.5.4 EX AMPLES OF T YPICAL INSTALLATIONS 2. From below, install a firestop supplied by the chimney manufacturer in each ceiling/floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above. 3. Follow the chimney’s manufacturers’ instructions and place the first chimney length on he fireplace.
  • Page 33 rain cap rain cap storm collar storm collar flashing chimney attic flashing attic chimney section wall band wall band radiation shield 1st floor offset support offset support insulated 1st floor elbow basement insulated insulated wall radiation shield chimney section elbow basement fireplace fireplace...
  • Page 34 rain cap chimney 10" strom collar less than 10 ft. flashing roof 10 ft. to nearest roofline minimum chimney height pitched roof recommended location recommended location marginal location location NOT recommended wall or parapet location NOT recommended 10 ft. or more less than 10 ft.
  • Page 35: List Of Mandatory Components

    follow manufactures´s 4.5.5 LIST OF MANDATORY 4.6 MASONRY instructions for maximum rain cap liner extension above COMPONENTS chimney 4.6.1 T YPICAL EXISTING MASONRY masonry chimney Chimney Components Type / Brand Part Number / must have WARNING structural Manufac- Product Code integrity turer Must have...
  • Page 36: Convection

    4.8 HEAT DISTRIBUTION SYSTEMS F. Alteration of the appliance in any manner is not Spartherm accepts no liability for installation or con- chimney permitted with the following exceptions; sequential damages. 1. External trim pieces which do not affect the oper-...
  • Page 37: Finishing

    5.1.1 VARIA M-60H 5.1.2 VARIA M-80H chimney chimney Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, left base brick, left base brick, right base brick, middle left rear wall brick, left base brick, right rear wall brick, middle bottom...
  • Page 38: 21 5.1.3 Varia M-100H

    5.1.3 VARIA M-100H 5.1.4 VARIA BH Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, left base brick, left base brick, middle left base brick, middle left base brick, right base brick, right base brick, middle right...
  • Page 39: 22 5.1.5 Arte Bh

    5.1.5 ARTE BH 5.1.6 VARIA 2L-80H Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, rear left base brick, right base brick, rear right base brick, middle right base brick, front left base brick, middle left base brick, front right...
  • Page 40: Varia 2R-80H

    5.1.7 VARIA 2R-80H 5.1.8 VARIA 2L-100H Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, left base brick, right base brick, middle left base brick, middle right base brick, middle right base brick, middle left base brick, right...
  • Page 41: Varia 2R-100H

    5.1.9 VARIA 2R-100H 5.1.10 VARIA B-FDH Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, left base brick, front left base brick, middle left base brick, rear left base brick, middle right base brick, front right base brick, right...
  • Page 42: Arte 3Rl-60H

    5.1.11 ARTE 3RL-60H 5.1.12 ARTE 3RL-80H Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, front left base brick, front left base brick, front right base brick, front right base brick, rear left base brick, rear left base brick, rear right...
  • Page 43: Arte 3Rl-100H

    5.1.13 ARTE 3RL-100H 5.1.14 ARTE U-50H-2016 Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, front left base brick, left base brick, front right base brick, right base brick, rear left rear wall brick, bottom base brick, rear right...
  • Page 44: Arte U-70H-2016

    5.1.15 ARTE U-70H-2016 5.1.16 ARTE U-90H-2016 Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name pos. name base brick, rear left base brick, rear left base brick, rear right base brick, rear right base brick, front right base brick, front left base brick, front left...
  • Page 45: Door Removal / Installation

    5.2 DOOR REMOVAL / INSTALLATION WARNING BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND/OR CHIMNEY FIRE. DO NOT STRIKE OR SLAM DOOR. NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT.
  • Page 46 pos. name quantity pulley flange bearing BG FL 1 1007754 cage nut M6 countersunk bolt M6x12 cheese head cap screw M6x10 cheese head cap screw M5x8 cheese head cap screw M5x8 set screw M10x8 set screw with point M5x10 cheese head cap screw M6x14 washer 12x6,4x1,6 pan-head screw M5x12 hood sheet, front...
  • Page 47 pos. name quantity flange bearing assembly, on ball bearings 1019702 cage nut M6 pressure screw M8x10 hexagon bolt M6x12 hexagon nut M6 cheese head cap screw M5x8 cheese head cap screw M6x10 cheese head cap screw M6x25 cheese head cap screw M6x14 washer 12x6,4x1,6 set screw M5x10 pulley, right...
  • Page 48 pos. name quantity roller fitting frame double sided, back Example shown: Varia B-FDh...
  • Page 49 pos. name hood sheet, left hood sheet, right hood sheet, front weight shaft sheet, right weight shaft sheet, left lock flap angle, rear left angle, rear right angle, front right angle, front left guide bar, right guide bar, left angle, bottom right weight rod angle, top left angle, top right...
  • Page 50: Operation

    At this point, the roaring fire that you see FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIM- Your Spartherm product is designed with the most advanced when the door is opened is wastefully drawing heated ILAR LIQUIDS TO START OR ‘FRESHEN UP’ A FIRE IN technology.
  • Page 51: Fire Extinguishers / Smoke Detectors

    6.1 FIRE EXTINGUISHERS / SMOKE 6.3 LIGHTING A FIRE the firebox or, if not present, to 50% of the fireboxes Firewood should be split, stacked in a manner that air DETECTORS backside height and burn at a medium low setting. The can get to all parts of it and covered in early spring to 6.3.1 FLASH FIRE whiteness of the bricks and the cleanliness of the glass...
  • Page 52: Smoking

    7.1 ASH REMOVAL PROCEDURES 7.2 CREOSOTE FORMATION AND REMOVAL WARNING When wood is burned too slow, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the IMPROPER DISPOSAL OF ASHES RESULTS IN FIRES. relatively cooler chimney flue of a slow-burning fire.
  • Page 53: Chimney Cleaning

    7.5.1 SINGLE FACED • Be careful not to overfire the appliance by leaving chimney should be cleaned. the door open too long after the initial start-up. • The appliance’s firebox and baffle system should pos. name A thermometer on the chimney connector and/or be cleaned if needed.
  • Page 54: Two Sided

    7.5.2 TWO SIDED pos. name button cold hand closing system, bottom cold hand closing system, top pressure spring set screw M5x12 cup spring 12,5 sheet metal screw thread 4,8x13 hexagon bolt with hexagon socket M6x25 hexagon bolt M6x30 raised countersunk head screw ST4,2x13 angle, top angle, bottom angle, top...
  • Page 55: Double Sided Front

    7.5.3 DOUBLE SIDED FRONT pos. name special bolt flat bar, bottom left flat bar, bottom right special bolt M5 bush hexagon bolt M4x10 sheet metal screw 4,2x19 angle, top angle, bottom seal 4x20x484 mm seal 4x20x930 mm seal 19x9 L=2880 mm glass Example shown: Varia B-FDh...
  • Page 56: Double Sided Back

    7.5.4 DOUBLE SIDED BACK pos. name washer 9x15 door support, bottom spring cold hand closing system special bolt cup spring 20 set screw M5x8 set screw M4x4 cheese head cap screw M4x8 sheet metal screw 4,2x19 door profile angle, top angle, bottom seal 19x9 L=2900 mm seal 4x20x495 mm...
  • Page 57: Three Sided

    7.5.5 THREE SIDED pos. name bolt break contact break contact glass strip, bottom front glass strip, top front glass, front glass, side glass strip, right glass strip, left glass strip, right rear glass strip, left rear glass strip, bottom left glass strip, bottom right glass strip, top left seal 2x20x1000 mm...
  • Page 58: Care Of Glass

    7.6 CARE OF GLASS 7.7 CLEANING THE GLASS CERAMIC 7.7.1 FLAT DOOR 4. Swing open the fireplace door to the left and/or SHEET right. WARNING 1. Close the fire compartment (slide down fully). 2. From the left, place the “operational tool” on the HOT GLASS WILL catch located centrally above the fire compartment WARNING...
  • Page 59: Replacements

    Contact your dealer or the factory for questions con- pos. name cerning prices and policies on replacement parts. Nor- fireplace insert, Varia M60h mally all parts can be ordered through your Authorized ash pan dealer / distributor. FOR WARRANTY REPLACEMENT...
  • Page 60: Varia M-80H

    8.2 VARIA M-80H pos. name fireplace insert, Varia M80h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate holder plate connection plate convection air port flue gas connection, height adjustible Ø200mm 3S-lever...
  • Page 61: Varia M-100H

    8.3 VARIA M-100H pos. name fireplace insert, Varia M100h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate ZCM, connection plate spacer flue gas connection, height adjustible Ø200mm convection air port...
  • Page 62: Varia Bh

    8.4 VARIA BH pos. name fireplace insert, Varia Bh ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall ZCM-module, top ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port 3S-lever operational tool, 45°...
  • Page 63: Arte Bh

    8.5 ARTE BH pos. name fireplace insert, Arte Bh ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate spacer connection plate convection air port fule gas connecting piece fule gas connecting Ø200mm...
  • Page 64: Varia 2L-80H

    8.6 VARIA 2L-80H pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
  • Page 65: Varia 2R-80H

    8.7 VARIA 2R-80H pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
  • Page 66: Varia 2L-100H

    8.8 VARIA 2L-100H pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
  • Page 67: Varia 2R-100H

    8.9 VARIA 2R-100H pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
  • Page 68: Varia B-Fdh

    8.10 VARIA B-FDH pos. name fireplace insert, Varia B-FDh ash pan ash grating ZCM-module, side wall left interior ZCM-module, side wall left exterior ZCM-module, side wall right interior ZCM-module, side wall right exterior ZCM-module, top ZCM, floor panel ZCM, front plate location ring spacer flue gas adapter...
  • Page 69: Arte 3Rl-60H

    8.11 ARTE 3RL-60H pos. name fireplace insert, Arte 3RL60h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top inner ZCM-module, top outer ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port...
  • Page 70: Arte 3Rl-80H

    8.12 ARTE 3RL-80H pos. name fireplace insert, Arte 3RL80h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port lever operational tool, 0°...
  • Page 71: Arte 3Rl-100H

    8.13 ARTE 3RL-100H pos. name fireplace insert, Arte 3RL100h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port lever operational tool, 0°...
  • Page 72: Arte U-50H-2016

    8.14 ARTE U-50H-2016 Pos. name fireplace insert, Arte U-50h-2016 ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall exterior ZCM-module, back wall interior ZCM-module, top exterior ZCM-module, top interior ZCM, floor panel ZCM, front plate location ring radiationshield spacer...
  • Page 73: Arte U-70H-2016

    8.15 ARTE U-70H-2016 Pos. name fireplace insert, Arte U-70h-2016 ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall exterior ZCM-module, back wall interior ZCM-module, top ZCM, floor panel ZCM, front plate location ring radiationshield spacer flue gas connection, height adjustible Ø250mm convection air port...
  • Page 74: Arte U-90H-2016

    8.16 ARTE U-90H-2016 Pos. name fireplace insert, Arte U-90h-2016 ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall exterior ZCM-module, back wall interior ZCM-module, top ZCM, floor panel ZCM, front plate location ring radiationshield spacer flue gas connection, height adjustible Ø250mm convection air port...
  • Page 75: Troubleshooting

    This quality manufactured product is state of the art. Your specialist dealer/contractor will gladly advise The materials used were meticulously selected and If such proof is not produced Spartherm Feuerung- and assist you in matters not covered by our warranty are constantly checked, as is our entire production stechnik GmbH shall not be obliged to honour the terms and conditions and undertakings.
  • Page 76: For Your Information

    10.6 FOR YOUR INFORMATION...
  • Page 77: For Your Information

    10.6 FOR YOUR INFORMATION...
  • Page 78: For Your Information

    10.6 FOR YOUR INFORMATION...
  • Page 79: Service History

    11. SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage. Date Dealer Name Service Technician Name Service Performed Special Concerns...