SAFETY INFORMATION • seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. • Do not burn green or freshly cut wood. WARNING • Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc.
TABLE OF CONTENTS 4.1.3. Double sided 5.1.1. Varia M-60h 7.5.2. Two sided 4.1.4. Three sided 5.1.2. Varia M-80h 7.5.3. Double sided front 4.2.1. Varia M-60h 5.1.3. Varia M-100h 7.5.4. Double sided back 1. Installation overview 4.2.2. Varia M-80h 5.1.4. Varia Bh 7.5.5 Three sided 4.2.3.
Page 4
TABLE OF CONTENTS 10.3. Requirement of effectiveness for the warranty 10.4. Warranty exclusions 10.5. Note 10.6. For your information 10.6. For your information 11. Service history...
1. INSTALLATION OVERVIEW 2. INTRODUCTION The Spartherm fireplaces have been tested and certified by CSA based on chimney connection the following standards: UL 127 / ULC S-610-M87. EPA : exempt from cur- convection air outlet rent legislation. Before installing your Spartherm fireplace, please contact...
Page 6
• temperature and should stay away to avoid burns or clothing ignition. • material in a safe manner. As with all plastic bags, these are not toys and • Young children should be carefully supervised when they are in the same should be kept away from children and infants.
DO NOT OVERFIRE – IF HEATER OR CHIMNEY CONNECTOR EVITER DE SURCHAUFFER – SI LE FEU OU LA CHEMINÉE GLOWS, YOU ARE OVERFIRING. DEVIENT ROUGE, VOUS SURCHAUFFEZ. Spartherm – v3, 01. Aug. 2016 DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE...
2.3. SPECIFICATIONS Fire chamber volume Minimum Power Maximum power Efficiency* Chimney type Unit weight ideal fuel size Varia M60h 2.53 ft 16500 BTU 31000 BTU >78% 8" 452 lbs 18" Varia M80h 3.5 ft 21500 BTU 40000 BTU >78% 8"...
• Non-toxic smoke will be emitted during the paint curing process, to help We suggest that our woodburning hearth products dissipate the smoke open a window near the appliance. be installed and serviced by professionals who are • Remove any dust or debris off the top of the appliance before firing the certified in the U.S.
Page 16
Example shown: Arte U-90h Example shown: Varia M80h is mandatory for: Varia Bh, B-FDh is mandatory for: Arte U-50h (-2016), U-70h (-2016), is mandatory for: Varia M60h, M80h, M100h, 2L-80h, 2R-80h, 2L-100h, 2R-100h and and Arte Bh U-90h (-2016) Arte 3RL60h, 3RL80h, 3RL100h...
2.7. DOOR OPENING 2.7.1. FLAT AND ANGLED DOOR 2.7.2. DOUBLE ANGLED DOOR Use the “operational tool” to open and close the door. Use the “operational tool” to open and close the door. holding fixture lever operational tool operational tool Position the “operational tool” Move the door up and down.
MUST BE UNRESTRICTED WHILE APPLIANCE IS IN USE TO PREVENT Please contact your dealer who offers suitable parts for air inlet ducts (pipes and damper). ROOM AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE AND AN INABILITY TO MAINTAIN A FIRE. SMOKE SPILLAGE CAN ALSO SET Make sure that the wire mesh is mounted at the combustion air inlet.
Page 19
Varia M60h 37 1/5" 16 1/2" 24 1/7" 84" Varia M80h 44 2/7" 16 1/2" 24 1/7" 84" Varia M100h 52 1/6" 16 1/2" 24 1/7" 84" Varia Bh 57 1/2" 16 1/2" 26 1/4" 84" Arte Bh 40 5/6"...
3.2. PLACEMENT NOTE! All grey colored parts have to be non combustible! NOTE! All grey colored parts have to be non combustible! 3.3. FLANGES AND ANCHOR PLATE NOTE!! the anchor plate is not included with the unit. Use only an chim- ney certified as UL 103HT or ULC S-629.
You must finish the front side of the fireplace using a cement board. CAUTION! Spartherm recommends the use of one piece cement board in place of multiple in order to avoid cracks. > Screw the cement board on the frame of the prefabricated shell.
To prevent any burning embers falling between the fireplace and the hearth extension from coming into contact with the floor, insert a metal sheet under the front of the fireplace. This Varia M60h Varia M80h Varia M100h...
4.1.3. DOUBLE SIDED Varia B-FDh 20” 12” 4.1.4 . THREE SIDED Arte Arte Arte Arte Arte Arte 3RL60h 3RL80h 3RL100h U-50h-2016 U-70h-2016 U-90h-2016 20" 20" 20" 20" 20" 20" 20" 20" 20" 20" 20" 20"...
4.3. CHIMNEY INSTALLATION • Deviations should be avoided whenever possible, especially the most pronounced. Each deviation adds some restriction to the chimney sys- This fireplace is designed and approved for installation with the following tem and may lead to draft problems. brands of chimneys measuring 8 and 10“...
The table below shows the minimum height requirements, fireplace included, 2. From below, install a firestop supplied by the chimney manufacturer in according to the number of elbows: each ceiling/floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above. chimney number of elbows minimum height...
Page 43
4.3.4. EX AMPLES OF T YPICAL INSTALLATIONS rain cap storm collar solin rain cap flashing storm collar attic attic radiation shield flashing attic attic radiation shield elbow 1st floor chimney section radiation shield 1st floor radiant shield chimney section wall radiation shield fireplace elbow basement...
Page 44
rain cap rain cap storm collar storm collar flashing chimney attic flashing attic chimney section wall band wall band radiation shield 1st floor offset support offset support insulated 1st floor elbow basement insulated insulated wall radiation shield chimney section elbow basement fireplace fireplace...
Page 45
rain cap chimney 10" strom collar less than 10 ft. flashing roof 10 ft. to nearest roofline minimum chimney height pitched roof recommended location recommended location marginal location location NOT recommended wall or parapet location NOT recommended 10 ft. or more less than 10 ft.
4.3.5. LIST OF MANDATORY COMPONENTS 4.4. MASONRY 4.4.1. T YPICAL EXISTING MASONRY Chimney Components Type / Brand Part Number / Manufacturer Product Code WARNING Must have rafter Super Vent 2100 protectors at the roof Selkirk level if the chimney JSC8RRS (8“) DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING is enclosed at the CF Sentinel...
follow manufactures´s the liner and insert onto the flue collar. Fasten with three screws. Secure the instructions for maximum rain cap liner extension above top of the liner to the chimney cap using a liner support and chimney flash- chimney ing.
4.5. CONVECTION outlet ports. Exceptions: Arte 3RL60h and Arte U-50h: only connect 2 gravity outlets 6 Spartherm stoves are convection stoves. Convection means that there is inch diameter. a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room (see drawing).The cold air (blue arrows) is...
4.6. HEAT DISTRIBUTION SYSTEMS chimney chimney chimney chimney 2" (min.) Gravity Distribution Kit The Gravity Distribution Kit may be used to heat rooms located above, behind and either side oft he room where the fireplace is located. Note that, if the hot air outlets are located at various levels, the heat will tend to seek the one at the highest level.
5.1.1. VARIA M-60h 5.1.2. VARIA M-80h pos. name base brick, left Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly base brick, middle left in numerical order! base brick, right base brick, middle right rear wall brick, left rear wall brick, middle bottom rear wall brick, middle top rear wall brick, right...
5.1.3. VARIA M-100h 5.1.4. VARIA Bh pos. name base brick, left Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in base brick, middle left numerical order! base brick, right base brick, middle right rear wall brick, middle left bottom rear wall brick, middle left top rear wall brick, middle bottom...
5.1.5. ARTE Bh 5.1.6. VARIA 2L-80h Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name base brick, right base brick, middle right base brick, middle left base brick, left side wall brick, right rear wall brick, right rear wall brick, middle bottom rear wall brick, middle top...
5.1.7. VARIA 2R-80h 5.1.8. VARIA 2L-100h pos. name pos. name base brick, left base brick, right Chamotte must be assembled Chamotte must be assembled base brick, middle left base brick, middle right strictly in numerical order! strictly in numerical order! base brick, middle right base brick, middle left base brick, right...
5.1.9. VARIA 2R-100h 5.1.10. VARIA B-FDh pos. name base brick, left Chamotte must be assembled Chamotte must be assembled strictly in numerical order! base brick, middle left strictly in numerical order! base brick, middle right base brick, right side wall brick, left rear wall brick, left rear wall brick, middle bottom pos.
5.1.11. ARTE 3RL-60h 5.1.12. ARTE 3RL-80h Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name base brick, front left pos. name base brick, front right base brick, front left base brick, rear left base brick, front right base brick, rear right base brick, rear left...
5.1.13. ARTE 3RL-100h 5.1.14. ARTE U-50h-2016 Chamotte must be assembled strictly in numerical order! Chamotte must be assembled strictly in numerical order! pos. name base brick, front left base brick, front right pos. name base brick, rear left base brick, left base brick, rear right base brick, right rear wall brick, right...
5.1.15. ARTE U-70h-2016 Chamotte must be assembled strictly in numerical order! pos. name base brick, rear left base brick, rear right base brick, front right base brick, front left rear wall brick baffle plate, rear left baffle plate, rear right baffle plate, front left baffle plate, front right...
5.1.16. ARTE U-90h-2016 Chamotte must be assembled strictly in numerical order! pos. name base brick, rear left base brick, rear right base brick, front left base brick, front right rear wall brick baffle plate, rear left baffle plate, rear right baffle plate, center left baffle plate, center right baffle plate, front left...
5.2. DOOR REMOVAL / INSTALLATION WARNING BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND/OR CHIMNEY FIRE. DO NOT STRIKE OR SLAM DOOR. NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT. pos.
Page 60
pos. name quantity pulley flange bearing BG FL 1 1007754 cage nut M6 countersunk bolt M6x12 cheese head cap screw M6x10 cheese head cap screw M5x8 cheese head cap screw M5x8 set screw M10x8 set screw with point M5x10 cheese head cap screw M6x14 washer 12x6,4x1,6 pan-head screw M5x12 hood sheet, front...
Page 61
pos. name quantity flange bearing assembly, on ball bearings 1019702 cage nut M6 pressure screw M8x10 hexagon bolt M6x12 hexagon nut M6 cheese head cap screw M5x8 cheese head cap screw M6x10 cheese head cap screw M6x25 cheese head cap screw M6x14 washer 12x6,4x1,6 set screw M5x10 pulley, right...
Page 62
pos. name quantity roller fitting frame double sided, back Example shown: Varia B-FDh...
Page 63
pos. name hood sheet, left hood sheet, right hood sheet, front weight shaft sheet, right weight shaft sheet, left lock flap angle, rear left angle, rear right angle, front right angle, front left guide bar, right guide bar, left angle, bottom right weight rod angle, top left angle, top right...
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHAR- COAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR ‘FRESHEN UP’ A Your Spartherm product is designed with the most advanced technology. The appli- FIRE IN THIS APPLIANCE. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE ance is extremely airtight.
Page 65
Can’t get the fire going? Slowly add larger wood (2x4 size pieces). Lay the pieces lengthwise from side to side in the hot coal bed with a shallow trench between, so that the primary air can Use more kindling and paper. Assuming the chimney and vent are sized flow directly into this trench and ignite the fuel above.
6.1. FIRE EXTINGUISHERS / SMOKE DETECTORS at a medium low setting. The whiteness of the bricks and the cleanliness of the glass are good indicators of your operating efficiency. Not enough heat All homes with a solid fuel burning appliance should have at least one fire is produced when only a few pieces of wood are burned or the wood may not extinguisher in a central location, known to all, and at least one smoke burn completely.
6.3. LIGHTING A FIRE Firewood should be split, stacked in a manner that air can get to all parts of it and covered in early spring to be ready for burning that fall. Dry firewood 6.3.1. FLASH FIRE has cracks in the end grain. Cut the wood so that it will fit horizontally, front to back, making for easier A flash fire is a small fire burned quickly when you don’t need much heat.
6.3.3. SMOKING A properly installed appliance should not smoke. If yours does, check the following: • Has the chimney had time to get hot? • Is the smoke passage blocked anywhere in the appliance, chimney con- nector or chimney? • Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
7.1. ASH REMOVAL PROCEDURES 7.2. CREOSOTE FORMATION AND REMOVAL When wood is burned too slow, it produces tar and other organic vapors, WARNING which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cooler chimney flue of a slow-burning IMPROPER DISPOSAL OF ASHES RESULTS IN FIRES.
• Do not burn green or freshly cut wood. Certain items and considerations are important in chimney cleaning: • Be careful not to overfire the appliance by leaving the door open too long after the initial start-up. A thermometer on the chimney connector and/ •...
7.5.1 SINGLE FACED pos. name special bolt bottom flat bar, left bottom flat bar, right special bolt bush hexagon bolt M4x10 sheet metal screw 4,2x19 angle, top angle, bottom glass seal 4x20x930 mm seal 19x9 L=2880 mm seal 4x20x484 mm door profile Example shown: Varia M100h...
7.5.2. TWO SIDED pos. name button cold hand closing system, bottom cold hand closing system, top pressure spring set screw M5x12 cup spring 12,5 sheet metal screw thread 4,8x13 hexagon bolt with hexagon socket M6x25 hexagon bolt M6x30 raised countersunk head screw ST4,2x13 angle, top angle, bottom angle, top...
7.5.3. DOUBLE SIDED FRONT pos. name special bolt flat bar, bottom left flat bar, bottom right special bolt M5 bush hexagon bolt M4x10 sheet metal screw 4,2x19 angle, top angle, bottom seal 4x20x484 mm seal 4x20x930 mm seal 19x9 L=2880 mm glass Example shown: Varia B-FDh...
7.5.4. DOUBLE SIDED BACK pos. name washer 9x15 door support, bottom spring cold hand closing system special bolt cup spring 20 set screw M5x8 set screw M4x4 cheese head cap screw M4x8 sheet metal screw 4,2x19 door profile angle, top angle, bottom seal 19x9 L=2900 mm seal 4x20x495 mm...
7.6. CARE OF GLASS pos. name pos. name bolt set screw M5x12 break contact washer 6,4 If the glass is not kept clean WARNING break contact washer 5,3 permanent discolouration and glass strip, bottom front hexagon cap nut M5 / or blemishes may result. HOT GLASS WILL glass strip, top front hexagon bolt M6x30...
7.7. CLEANING THE GLASS CERAMIC SHEET 7.7.1. FLAT DOOR 1. Close the fire compartment (slide down fully). WARNING 2. From the left, place the “operational tool” on the catch located centrally above the fire compartment door. THE GLASS CERAMIC SHEET MAY ONLY BE CLEANED WHEN COLD 3.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be improved if Another locking bolt is located on the assembly is warmed, using a hair dryer or similar heat source. the opposite side.
8.1. VARIA M-60h pos. name fireplace insert, Varia M60h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall ZCM-module, top ZCM, floor panel ZCM, front plate holder plate spacer flue gas connection, height adjustible Ø200mm...
8.2. VARIA M-80h pos. name fireplace insert, Varia M80h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate holder plate connection plate convection air port flue gas connection, height adjustible Ø200mm 3S-lever...
8.3. VARIA M-100h pos. name fireplace insert, Varia M100h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate ZCM, connection plate spacer flue gas connection, height adjustible Ø200mm convection air port...
8.4. VARIA Bh pos. name fireplace insert, Varia Bh ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall ZCM-module, top ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port 3S-lever operational tool, 45°...
8.5. ARTE Bh pos. name fireplace insert, Arte Bh ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate spacer connection plate convection air port fule gas connecting piece fule gas connecting Ø200mm...
8.6. VARIA 2L-80h pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
8.7. VARIA 2R-80h pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
8.8. VARIA 2L-100h pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
8.9. VARIA 2R-100h pos. name ZCM, front plate ZCM, floor panel ZCM, position ring ash pan ash grating ZCM-module, side wall ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top spacer convection air port mantel guideway, round flue gas connection, height adjustible Ø250mm air box with closed primary air flap air valve, fixed mesh for small animals, round...
8.10. VARIA B-FDh pos. name fireplace insert, Varia B-FDh ash pan ash grating ZCM-module, side wall left interior ZCM-module, side wall left exterior ZCM-module, side wall right interior ZCM-module, side wall right exterior ZCM-module, top ZCM, floor panel ZCM, front plate location ring spacer flue gas adapter...
8.11. ARTE 3RL-60h pos. name fireplace insert, Arte 3RL60h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top inner ZCM-module, top outer ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port...
8.12. ARTE 3RL-80h pos. name fireplace insert, Arte 3RL80h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port lever operational tool, 0°...
8.13. ARTE 3RL-100h pos. name fireplace insert, Arte 3RL100h ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall left ZCM-module, back wall right ZCM-module, top ZCM, floor panel ZCM, front plate spacer flue gas connection, height adjustible Ø250mm convection air port lever operational tool, 0°...
8.14. ARTE U-50h-2016 Pos. name fireplace insert, Arte U-50h-2016 ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall exterior ZCM-module, back wall interior ZCM-module, top exterior ZCM-module, top interior ZCM, floor panel ZCM, front plate location ring radiationshield spacer...
8.15. ARTE U-70h-2016 Pos. name fireplace insert, Arte U-70h-2016 ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall exterior ZCM-module, back wall interior ZCM-module, top ZCM, floor panel ZCM, front plate location ring radiationshield spacer flue gas connection, height adjustible Ø250mm convection air port...
8.16. ARTE U-90h-2016 Pos. name fireplace insert, Arte U-90h-2016 ash pan ash grating ZCM-module, side wall left ZCM-module, side wall right ZCM-module, back wall exterior ZCM-module, back wall interior ZCM-module, top ZCM, floor panel ZCM, front plate location ring radiationshield spacer flue gas connection, height adjustible Ø250mm convection air port...
Wood burns too fast. • Air control may need to be adjusted down. Spartherm Feuerungstechnik GmbH gives a 24-month warranty on elevating • Check to see ash plug is properly seated (if equipped). mechanisms, operating devices such as handles, adjustment levers, shock •...
• installation that does not comply with industry practice on installation warranty claim. instructions 10.5. NOTE If such proof is not produced Spartherm Feuerungstechnik GmbH shall not be obliged to honour the warranty. Your specialist dealer/contractor will gladly advise and assist you in matters 10.4. WARRANT Y EXCLUSIONS not covered by our warranty terms and conditions and undertakings.
11. SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage. Date Dealer Name Service Technician Name Service Performed Special Concerns...
Page 100
SPARTH ERM THE GLOBAL BRAND FOR YOUR LIVING ROOM Your specialist dealer Spartherm Feuerungstechnik GmbH · Maschweg 38 · D-49324 Melle Phone +49 (0) 5422 94 41-0 · Fax +49 (0) 5422 9441-14 · www.spartherm.com...