3.2 PLACEMENT
NOTE! All grey colored parts have to be non combustible!
3.3 FLANGES AND ANCHOR PLATE
NOTE!! the anchor plate is not included with the unit. Use only
an chimney certified as UL 103HT or ULC S-629. Be sure to
place the convection and exhaust connectors before placing
the top elements of the insulation shell. The dimensions and
positioning of the different air inlet and outlet are available in
the table in chapter „dimensions".
NOTE! All grey colored parts have to be non combustible!
3.4 FRONT CHASE
You must finish the front side of the fireplace using a
cement board.
CAUTION!
Spartherm recommends the use of one piece cement
board in
place of multiple in order to avoid cracks.
> Screw the cement board on the frame.
> Finish the wall.
> Place L or J finishing trim to obtain sharp
angles.
> Plaster
19
NOTE! All grey colored parts have to be non combustible!
NOTE! Do only use non combustible materials 6 inch surroun-
ding the convection air grills.