2.3 SPECIFICATION

Fire chamber volume
Varia M60h
2.53 ft
Varia M80h
3.5 ft
Varia M100h
4.11 ft
Varia Bh
4.28 ft
Arte Bh
4.2 ft
4.14 ft
Varia 2L/2R-80h
Varia 2L/2R-100h
4.16 ft
6.83 ft
Varia B-FDh
Arte 3RL60h
2.71 ft
4.38 ft
Arte 3RL80h
Arte 3RL100h
5.88 ft
Arte U-50h-2016
2.67 ft
Arte U-70h-2016
3.94 ft
Arte U-90h-2016
6.1 ft
Conversion Factors
Inches to millimeters (mm): 1'' = 25.4 mm
British Thermal Unit
BTU/h to Watt: 1BTU/h = 0.293 Watt
Kilogramm to Pound: 1kg = 2.205 lb
Cubicmeter to cubicfeet: 1m
3
= 35.314 ft
3

2.4 GENERAL INSTRUCTIONS

WARNING
THIS APPLIANCE HAS NOT BEEN TESTED WITH
ANY VENTED OR UNVENTED GAS LOG SET: TO
REDUCE RISK OF FIRE OR PREVENT INJURY, DO
NOT INSTALL A VENTED OR UNVENTED GAS LOG
SET INTO THE APPLIANCE.
Minimum Power
Maximum power
3
16500 BTU
21500 BTU
3
3
26000 BTU
25000 BTU
3
3
26000 BTU
25000 BTU
3
3
26500 BTU
26500 BTU
3
3
19000 BTU
21500 BTU
3
26000 BTU
3
3
21500 BTU
26000 BTU
3
3
31000 BTU
CAUTION:
The decorative gas appliance shall be installed in accordance
with the Natural Gas Installlation Code, CAN/CGA-B149.1-M95.
The installation shall include the word "CAUTION" and the
following or equivalent statement: "Gas logs shall be certified
for the application. When installed, the chimney damper shall
be permanently secured in an open position to effectively vent
the appliance".
The logsets need to be certified to ansi z21.60/
csa2.26-2017 to be installed in their fireplaces. Do not operate
an gas log set in this fireplace with the chimney removed. State-
ment to keep door fully open when gas log are used.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
THIS APPLIANCE AND THE COMPONENTS ARE
DESIGNED TO BE INSTALLED AND OPERATED AS A
SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR
ITEMS IN THIS SYSTEM, UNLESS ALLOWED BY THESE
INSTALLATION INSTRUCTIONS, WILL VOID THE LISTING
AND MAY VOID THE PRODUCT WARRANTY. IT MAY
ALSO CREATE A HAZARDOUS INSTALLATION. READ
THROUGH THESE INSTRUCTIONS THROUGHLY BEFORE
STARTING YOUR INSTALLATION AND FOLLOW THEM
CAREFULLY THROUGHOUT YOUR PROJECT.
Efficiency*
31000 BTU
>78%
40000 BTU
>78%
49000 BTU
>78%
46000 BTU
>78%
49000 BTU
>78%
46000 BTU
>80%
49000 BTU
>78%
49000 BTU
>78%
33500 BTU
>80%
40000 BTU
>80%
49000 BTU
>78%
40000 BTU
80%
49000 BTU
>78%
57500 BTU
>78%
Before beginning your installation, consult with your
local building code agency or fire officials and insurance
representative to ensure compliance.
• Non-toxic smoke will be emitted during the paint
curing process, to help dissipate the smoke open a
window near the appliance.
• Remove any dust or debris off the top of the appli-
ance before firing the appliance as the paint will
become soft as the appliance heats up and will
harden as the appliance cures. To cure the paint on
your appliance burn your appliance moderately hot
during the first few fires.
12
Chimney type
Unit weight
8"
452 lbs
8"
662 lbs
8"
772 lbs
10"
772 lbs
8"
573 lbs
10"
606 lbs
10"
617 lbs
10"
772 lbs
10"
551 lbs
10"
617 lbs
10"
662 lbs
10"
529 lbs
10"
827 lbs
10"
1023 lbs
• To keep the gasket from sticking to the appliance
as the paint is curing, periodically open the door
every 5-10 minutes.
• For the first two weeks use generous amounts
of fuel and burn the appliance for an hour as the
appliance goes through a process of eliminating
moisture in the steel and firebricks. The initial heat
output will be reduced while the moisture is bring
drawn from the appliance and it will be necessary
to build several hot fires to remove this moisture.
DURING THIS PROCESS DO NOT OVERFIRE THE
APPLIANCE.
ideal fuel size
18"
18"
18"
18"
20"
18"
18"
18"
20"
20"
20"
18"
18"
18"

Hide quick links: