Finishing; 21 5.1 Bricks And Baffels Installation; 21 5.1.1 Varia M-60H; 21 5.1.2 Varia M-80H - Spartherm Varia M60h Installation And Operating Instructions Manual

Table of Contents

Advertisement

chimney
chimney
Gravity Distribution Kit
The Gravity Distribution Kit may be used to heat rooms
located above, behind and either side oft he room
where the fireplace is located. Note that, if the hot air
outlets are located at various levels, the heat will tend
to seek the one at the highest level. It is not permitted
to connect two ducts together.

5. FINISHING

5.1 BRICKS AND BAFFELS
INSTALLATION
WARNING
OPERATION OF THE APPLIANCE WITHOUT THE BAF-
FLES CAN RESULT IN EXCESSIVE TEMPERATURES
THAT COULD DAMAGE THE APPLIANCE, CHIMNEY
AND THE SURROUNDING ENCLOSURE.
NOTE: DO NOT OPERATE IF BAFFLE AND MANIFOLD
SHIELD ARE NOT IN POSITION.
5.1.1 VARIA M-60H
Chamotte must be assembled strictly in numerical order!
pos.
name
1
base brick, left
2
base brick, right
3
rear wall brick, left
4
rear wall brick, middle bottom
5
rear wall brick, middle top
6
rear wall brick, right
7
side wall brick, right
8
side wall brick, left
9
baffle plate
3
8
1
2
5.1.2 VARIA M-80H
Chamotte must be assembled strictly in numerical order!
pos.
1
2
3
4
5
6
7
8
9
10
11
9
10
5
4
6
1
7
37
name
base brick, left
base brick, middle left
base brick, right
base brick, middle right
rear wall brick, left
rear wall brick, middle bottom
rear wall brick, middle top
rear wall brick, right
side wall brick, right
side wall brick, left
baffle plate
5
11
7
6
2
4
3
8
9

Hide quick links: