Agitator Kit Accessory - Graco Pro Xp 60 AA WB Instructions - Parts Manual

Isolation system
Table of Contents

Advertisement

Installation
Agitator Kit
Kit Accessory
Accessory
Agitator
Agitator
Kit
Accessory
To add an agitator to the Graco isolation system, order
Part No. 245895. See
245895 Agitator Kit, page
for the kit parts list.
1. Discharge the system voltage (see
Discharge and Grounding Procedure, page
2. Relieve the pressure (see
Pressure Relief Procedure, page
3. Open the isolated enclosure door.
4. Remove the back of the control box (258).
5. Remove tube (A2) from elbow (282) at the air
manifold; see
Tubing and Wiring , page
Install the Y fitting (402) into the elbow. Install
tubes (A2) and (407) into the Y fitting. Route the
agitator tube (407) into the cabinet.
6. Replace the back of the control box (258).
7. Assemble the other parts of the kit as shown.
Secure the agitator with the setscrew (408).
8. Return the system to service.
22
72,
Fluid Voltage
29).
28).
62.
Figure 14 245895 Agitator Kit
3A2497H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wb3000H60t18H60m18

Table of Contents