Operation
Fill the
the Fluid
Fluid Supply
Supply
Fill
Fill
the
Fluid
Supply
1. Follow the
Fluid Voltage Discharge and
Grounding Procedure, page
2. Follow the
Pressure Relief Procedure, page
3. Open the isolated enclosure door.
4. Remove the pail cover from the pail, holding a rag
over the suction tube strainer to prevent any fluid
from dripping into the isolated enclosure. Place
the cover and suction tube outside the enclosure.
5. Remove the supply pail from the enclosure.
NOTICE
NOTICE
NOTICE
Be sure to wipe up all fluid spills in the isolated
enclosure. Fluid can create a conductive path
and cause the system to short out.
6. Clean up any fluid spills in the enclosure, using
a soft cloth and a non-flammable, compatible
solvent.
7. Fill the supply pail with fluid and return it to the
enclosure. Clean up any spills.
8. Reinstall the pail cover, holding a rag over the
suction tube strainer to prevent fluid spills while
you place the pump suction tube in the pail.
9. Close the isolated enclosure door and fasten
securely with the T-handle locking screw.

Startup

Startup
Startup
Follow all steps under
Gun Setup Procedure, page
Check the following list daily, before starting to
operate the system, to help ensure you of safe,
efficient operation.
• All operators are properly trained to safely operate
an automatic electrostatic air spray system as
instructed in this manual.
• All operators are trained in the
Pressure Relief Procedure, page
• The warning sign provided with the gun is mounted
in the spray area where it can be easily seen and
read by all operators.
• The system is thoroughly grounded and the
operator and all persons entering the spray area
are properly grounded. See
30
29.
28.
23.
28.
Grounding, page
16.
• The condition of the gun's electrical
components has been checked as instructed in
Electrical Tests, page
• Ventilation fans are operating properly.
• Workpiece hangers are clean and grounded.
• All debris (including flammable fluids and rags) is
removed from the spray area.
• All flammable fluids in the spray booth are in
approved, grounded containers.
• All conductive objects in the spray area are
electrically grounded and the floor of the spray
area is electrically conductive and grounded.

Shutdown

Shutdown
Shutdown
To reduce the risk of an injury, follow the
Pressure Relief Procedure, page 28
are instructed to relieve the pressure.
1. Discharge the system voltage. See
Discharge and Grounding Procedure, page
2. Flush the gun. See
3. Follow the
Pressure Relief Procedure, page
4. Hang the gun from its hook, with the nozzle
pointing down. Be sure to keep the gun from
grounding out.
36.
whenever you
Fluid Voltage
Flushing, page
31.