Maintenance; Daily Care And Cleaning Checklist; Flushing - Graco Pro Xp 60 AA WB Instructions - Parts Manual

Isolation system
Table of Contents

Advertisement

Maintenance

Maintenance
Maintenance
Daily Care
Care and
and Cleaning
Cleaning Checklist
Daily
Daily
Care
and
Cleaning
Check the following list daily upon completion of
equipment usage.
Flush the gun. See
Clean the fluid and air line filters.
Clean the outside of the gun. See
Clean the Gun Daily, page
Clean the air cap and spray tip daily, at
a minimum. Some applications require
more frequent cleaning. Replace the spray
tip and air cap if they are damaged. See
Clean the Gun Daily, page
Check the electrode and replace
if broken or damaged. See
Electrode Replacement, page
Check for fluid leakage from the gun and fluid
hoses. Tighten fittings or replace equipment
as needed.
Check electrical grounding. See
Check Gun Electrical Grounding, page
3A2497H
Checklist
Checklist
Flushing, page
31.
33.
33.
45.
26.

Flushing

Flushing
Flushing
• Flush before changing fluids, before fluid can dry
in the equipment, at the end of the day, before
storing, and before repairing equipment.
• Flush at the lowest pressure possible. Check
connectors for leaks and tighten as necessary.
• Flush with a non-flammable solvent that is
compatible with the fluid being dispensed and the
equipment wetted parts.
To reduce the risk of fire, explosion, or electric
shock, turn OFF (O) the ES On-Off switch before
flushing the gun.
Follow the
Fluid Voltage Discharge and Grounding
Procedure, page
29, before flushing.
Only flush, purge, or clean the gun with fluids that
meet the following flammability requirements:
FM, FMc
FMc Approved:
Approved:
• FM,
FM,
FMc
Approved:
Material does not sustain burning in accordance
with the Standard Test Method for Sustained
Burning of Liquid Mixtures, ASTM D4206.
CE- - - EN
EN 50059
50059 Compliant:
Compliant:
• CE
CE
EN
50059
Compliant:
Material is classified as non-ignitable as defined
by EN 50059: 2018.
For more information, see
Ignitability of Coating Materials, page
NOTICE
NOTICE
NOTICE
Only use non-flammable solvents when flushing
or cleaning equipment.
1. Turn OFF (O) the ES On-Off switch. Wait 30
seconds for the voltage to bleed off.
2. Discharge the system voltage. See
Discharge and Grounding Procedure, page
3. Follow the
Pressure Relief Procedure, page
Maintenance
73.
Fluid Voltage
29.
28.
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wb3000H60t18H60m18