Parameter Access - Rinnai RS100 Training Program

Condensing boiler controller
Table of Contents

Advertisement

Parameter Access

There are two levels of access for making parameter changes:
• The user level allows clock and timer changes and basic system changes
• To access this level, hold the rotary dial for approximately 3 seconds
• The installer level allows access for all pertinent parameters
• To access this level, hold the heating and DHW buttons imultaneously
for approximately 3 seconds
• Code access will then display—using the dial to enter each digit, enter
code ―1234‖
• Installer access is then granted:
• At this point, repeat the user level access
procedure to enter the parameter menus--with
this code, user level and installer level will be
accessible
• After 2 Minutes of inactivity, these menus will be
exited automatically (this value can be changed)
seconds for consumer level
www.rinnai.us • © 2009 Rinnai America Corporation
Hold the rotary dial for 3
parameter access
Hold the heating
and DHW buttons
simultaneously for
3 seconds for
installer level
access