Rinnai RS100 Training Program page 13

Condensing boiler controller
Table of Contents

Advertisement

RS100 Operational Modes
This allows selection of unique operational modes-a cursor is displayed above the selected mode.
Any unique operating mode and its settings will be cancelled when a new unique mode is selected.
Vacation mode-Heating will
be inactive until the specified
date (this example is
September 24).At 0:00
(midnight) on this date,
operation will resume. This
can be set 250 days in
advance. DHW operation is
set to freeze protection
(100°F default).
NOTE: During normal operation in RC mode, the area/room temperature is displayed—not the set point.
Absent / Economy setback-
Heating will be inactive until
specified time (this example is
10:27 am). This can be set
between 0.5-24 hours OR if P1
is selected, heating will resume
at the ON point of the next
heating event.
NOTE: While in these modes, a brief press of the dial will allow
www.rinnai.us • © 2009 Rinnai America Corporation
Party mode-Heating will
remain in operation until
specified time (this example
is 10:27 am). This can be
set between 0.5-24 hours
OR if P1 is selected, heating
will resume at the ON point
of the next heating event.
immediate temperature adjustment.
Operating Times-Heating
and DHW will operate based
on the times and
temperatures set in the
―Timeprograms‖ chapter. If
P1-P3 is selected, there will
be up to three different
schedules to select.
13