Reference Temperature Probe Defect; Ice Damage Risk - Henny Penny SmartCombi ESC 615 Troubleshooting Manual

Error messages & troubleshooting electric and gas combi
Hide thumbs Also See for SmartCombi ESC 615:
Table of Contents

Advertisement

SmartCombi™ Service

Reference temperature probe defect

Consequence:
The unit is out of order. The reference temp. probe on the keyboard pcb has broken.
Troubleshooting:
Change keyboard pcb.

Ice damage risk

Consequence:
The unit is out of order. A temperature of < 0°C (32°F) has measured on the keyboard pcb.
Position of the temperature probe:
The probe is located .
Troubleshooting:
Ensure that the temperature next to the unit is not less than < 0°C (32°F). Perhaps change oven
location.
Caution! There is a high risk that water pressurized components were damaged.