Hw-Fail Temp Uref0 To High; Error Power Board; Waterfilter Maintenance - Henny Penny SmartCombi ESC 615 Troubleshooting Manual

Error messages & troubleshooting electric and gas combi
Hide thumbs Also See for SmartCombi ESC 615:
Table of Contents

Advertisement

SmartCombi™ Service
Error description:
The error signalled, that the supply line is disturbed on the circuit board and/or from sensors. A sensor
has a very low resistor or direct chassis ground contact with the frame.
The first possibility is likely if the fault occurs during WaveClean or in steaming mode. Explanation:
The water gets into the probe and builds up an electric connection between the probe itself and the
chassis. Through this connection a voltage potential from the chassis reaches the temperature inputs of
the keyboard pcb and causes the malfunction.
Troubleshooting:
Disconnect the following components one by one to identify the faulty component:
Pressure switch B10 at the steaming unit
Core temperature probe B1
Drain probe B4
Chamber probe B2
Chamber probe B3 (only at floor unit 20.x)
If the fault appears only at the automatic cleaning WaveClean, the drain probe B4 is probably the
cause.
Check power supply of the relay
card (transformer T1 and relay
card plug X3). Also see „Layout
of the relay card"
Description:
There is a communication error between keyboard and relay pcb.
Troubleshooting:
Check power supply of the relay
card (transformer T1 and relay
card plug X3). Also see „Layout
of the relay card"
The water quantity maintenance was activated in the user level (password 111). The adjusted water
quantity has flown by the soft water assembly.
Change water softener and enter the capacity in the corresponding level (password 111, water limit
maintenance).

HW-Fail Temp UREF0 to high

Change relay pcb.

Error Power board

Change relay pcb.

Waterfilter maintenance

Change keyboard pcb.. Mount the old
relay pcb again.
Change keyboard pcb.. Mount the old
relay pcb again.