Table 1.0 Command ID
www.kiwitechnics.com
Data Byte
$b9 (185)=Upper DCO1 Initial PWM
Amount
$ba (186)=Upper DCO2 DYN Amount
$bb (187)=Upper DCO2 Control
$bc (188)=Upper Detune Initial
Amount
$bd (189)=Upper DCO1 Initial Mix
Level
$be (190)=Upper DCO2 Initial Mix
Level
$bf (191)=Upper DCO2 Mix DYN Amount 0xxxxxxx
$c0 (192)=Upper DCO2 Initial Mix
Env Amount
$c1 (193)=Upper DCO2 Mix Control
$c2 (194)=Upper HPF Initial Level
$c3 (195)=Upper VCF Initial Cutoff
Hi
$c4 (196)=Upper VCF Initial Cutoff
Lo
$c5 (197)=Upper VCF Initial
Resonance Hi
$c6 (198)=Upper VCF Initial
Resonance Lo
$c7 (199)=Upper VCF Initial LFO
Amount
$c8 (200)=Upper VCF Initial ENV
Amount
$c9 (201)=Upper VCF Initial KEY
Amount
$ca (202)=Upper VCF DYN Amount
Data Type
Data Details
Byte details
7 ------- 0
0xxxxxxx
x = Range $00-$7f (0-127)
0xxxxxxx
x = Range $00-$7f (0-127)
0ww0yyzz
zz =
DCO1Env(00=Env1,01=Env2,10=Env3)
yy =
DCO1LFO(00=LFO1,01=LFO2,10=LFO3)
ww =
DCO1PWM Src(00=Env1,01=Env3,10=LFO2,11=LFO3)
0xxxxxxx
x = Range $00-$7f (0-127)
0xxxxxxx
x = Range $00-$7f (0-127)
0xxxxxxx
x = Range $00-$7f (0-127)
x = Range $00-$7f (0-127)
0xxxxxxx
x = Range $00-$7e (-63 → 0 → +63) - ($7f=$7e)
000000zz
zz =
MixEnv(00=Env1,01=Env2,10=Env3)
000000xx
xx =
0-3
000xxxxx
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
000xxxxx + 0yyyyyyy = 0000xxxx xyyyyyyy
x = Range $0-$fff (0-4095)
000xxxxx
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
000xxxxx + 0yyyyyyy = 0000xxxx xyyyyyyy
x = Range $0-$fff (0-4095)
0xxxxxxx
x = Range $00-$7e (-63 → 0 → +63) - ($7f=$7e)
0xxxxxxx
x = Range $00-$7e (-63 → 0 → +63) - ($7f=$7e)
0xxxxxxx
x = Range $00-$7e (-63 → 0 → +63) - ($7f=$7e)
0xxxxxxx
x = Range $00-$7f (0-127)