Function Blocks
3.2.56 ODD - Operator Display for Discrete Indication & Control
ODD function blocks are one of five operator displays that
can be used on a one per loop basis to configure the local
operator display functions as well as network parameters.
See the i|ware PC faceplate example on the next page.
The ODD function block displays up to 16 discrete
variables. Each input has a corresponding block output
that is equal to the input when the variable mode is in
Auto. Each input variable can be assigned a mode. The
value of the output can be changed while in Man by using
the pulser and pressing the ACK button. When a variable
is switched to Manual it will always equal the input value
until changed.
The LOOP # parameter is used to index reads and writes
to Modbus parameters. See Section 5 for more
information on network parameters.
The VIEW OD parameter, when set to YES enables the
operator display to be viewed and accessed locally. In
cases where it is desired to view display or operation
parameters only from a network workstation, the
parameter should be set to NO.
During a cold or warm start, each input variable will
power up in the auto mode. During a hot start, the mode
and manual value will equal the value prior to power
down.
Each discrete input variable can be displayed on the local
faceplate using the D button. When first stepping into a
loop using the Loop button, the loop tag will be displayed
(e.g. DigDisp1). Pressing the D button will scroll through
the discrete points displaying the point tag (e.g. SV-103)
in the alphanumeric and the value of the input on the left 3
positions of the digital display (e.g. On) and the output in
the right most 3 positions (e.g. OFF).
The A/M button will display the point mode and enable
switching the point between auto & manual using the A/M
button. The manual value can be changed by turning the
pulser and pressing the ACK button. If the ACK button is
not pressed within 4-5 seconds, the display will return to
the actual output value.
3-56
.
Operator Display for Discrete indication & control
ODD_
I 0
Input 0
I 1
Input 1
I 2
Operator Display
Input 2
I 3
Input 3
Discrete indication
I 4
Input 4
I 5
Input 5
control
I 6
Input 6
I 7
Input 7
I 8
Input 8
I 9
Input 9
I A
Input A
I B
Input B
I C
Input C
I D
Input D
I E
Input E
I F
Input F
I
0
T A G
Input 0 TAG
(S)
I
1
T A G
Input 1 TAG
(S)
I
2
T A G
Input 2 TAG
(S)
I
3
T A G
Input 3 TAG
(S)
I
4
T A G
Input 4 TAG
(S)
I
5
T A G
Input 5 TAG
(S)
I
6
T A G
Input 6 TAG
(S)
I
7
T A G
Input 7 TAG
(S)
I
8
T A G
Input 8 TAG
(S)
I
9
T A G
Input 9 TAG
(S)
I
A
T A G
Input A TAG
(S)
I
B
T A G
Input B TAG
(S)
I
C
T A G
Input C TAG
(S)
I
D
T A G
Input D TAG
(S)
I
E
T A G
Input E TAG
(S)
I
F
T A G
Input F TAG
(S)
L
O
O P
#
LOOP #
................................................ 01 to 25
(S)
V
I E
W
O D
VIEW Operator Display
I N P U T
0
INPUT 0
.........................
(H)
I
N
P
U
T
1
INPUT 1
..........................
(H)
I
N
P
U
T
2
INPUT 2
.........................
(H)
I
N
P
U
T
3
INPUT 3
.........................
(H)
I
N
P
U
T
4
INPUT 4
.........................
(H)
I N P U T
5
INPUT 5
.........................
(H)
I
N
P
U
T
6
INPUT 6
..........................
(H)
I
N
P
U
T
7
INPUT 7
.........................
(H)
I
N
P
U
T
8
INPUT 8
.........................
(H)
I
N
P
U
T
9
INPUT 9
.........................
(H)
I N P U T
A
INPUT A
.........................
(H)
I N P U T
B
INPUT B
.........................
(H)
I
N
P
U
T
C
INPUT C
..........................
(H)
I
N
P
U
T
D
INPUT D
.........................
(H)
I
N
P
U
T
E
INPUT E
.........................
(H)
I
N
P
U
T
F
INPUT F
.........................
(H)
UM353-1B
O0
Output 0
O1
Output 1
O2
Output 2
for
O3
Output 3
O4
Output 4
&
O5
Output 5
O6
Output 6
O7
Output 7
Output 8
O8
O9
Output 9
Output A
OA
Output B
OB
Output C
OC
Output D
OD
Output E
OE
Output F
OF
WD
Watch Dog
................................. 6 ASCII Char
( I0 TAG)
................................. 6 ASCII Char
( I1 TAG)
................................. 6 ASCII Char
( I2 TAG)
................................. 6 ASCII Char
( I3 TAG)
................................. 6 ASCII Char
( I4 TAG)
................................. 6 ASCII Char
( I5` TAG)
................................. 6 ASCII Char
( I6 TAG)
................................. 6 ASCII Char
( I7 TAG)
................................. 6 ASCII Char
( I8 TAG)
................................. 6 ASCII Char
( I9 TAG)
................................. 6 ASCII Char
( IA TAG)
................................. 6 ASCII Char
( IB TAG)
................................. 6 ASCII Char
( IC TAG)
................................. 6 ASCII Char
( ID TAG)
................................. 6 ASCII Char
( IE TAG)
................................. 6 ASCII Char
( IFTAG)
(null)
...................... NO/YES
YES
(H)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
loop tag.block tag.output
(null)
Rev. 3
April 2012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents