Parker PDHX-E Series User Manual page 90

Table of Contents

Advertisement

The format for the trace mode display is:
Sequence Number
Step 5
To exit the trace mode, enter the following command:
Single-Step Mode
You can debug your program with another level of debugging using the Single-Step mode.
Single-Step mode allows you to execute one command at a time when you want the
command to be executed. Use the XST command to enable Single-Step mode. Once you
are in the mode, you can execute a sequence one command at a time. To execute a
command, you must use the # sign. By entering a # followed by a delimiter, you will execute
the next command in the sequence. If you follow the # sign with a number (n) and a delimiter,
you will execute the next n commands. The following steps illustrate the use of Single Step
mode:
Step 1
Enter Single-Step mode
XST1
Step 2
Begin execution of sequence #1
XR1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
*SEQUENCE 003 COMMAND D50000 LOOP COUNT 1
*SEQUENCE 003 COMMAND G LOOP COUNT 1
*SEQUENCE 003 COMMAND XT LOOP COUNT 1
*SEQUENCE 001 COMMAND N LOOP COUNT 1
*SEQUENCE 001 COMMAND GOSUB3 LOOP COUNT 2
*SEQUENCE 003 COMMAND D50000 LOOP COUNT 2
*SEQUENCE 003 COMMAND G LOOP COUNT 2
*SEQUENCE 003 COMMAND XT LOOP COUNT 2
*SEQUENCE 001 COMMAND N LOOP COUNT 2
*SEQUENCE 001 COMMAND GOSUB3 LOOP COUNT 3
*SEQUENCE 003 COMMAND D50000 LOOP COUNT 3
.
.
.
.
.
*SEQUENCE 003 COMMAND G LOOP COUNT 5
*SEQUENCE 003 COMMAND XT LOOP COUNT 5
*SEQUENCE 001 COMMAND N LOOP COUNT 5
*SEQUENCE 001 COMMAND XT